The evaluation of fifty percent breakdown voltage across Iranian 400 kV transmission line insulators

B. Vahidi, M. Abedi, S. H. Hosseinian
{"title":"The evaluation of fifty percent breakdown voltage across Iranian 400 kV transmission line insulators","authors":"B. Vahidi, M. Abedi, S. H. Hosseinian","doi":"10.1109/ICPADM.1991.172065","DOIUrl":null,"url":null,"abstract":"The Iranian isokeraunic map developed by the authors is presented. A statistical analysis of tower footing resistances of 400 kV lines in the Iranian national grid is also presented. An attempt has been made to evaluate lightning fifty-percent breakdown voltage (V/sub 50/) across 400 kV insulators in Iran, according to obtained keraunic levels and probabilistic results of tower footing resistances. A comparison between calculated V/sub 50/ and V/sub 50/ of presently installed insulators of 400 kV lines in the Iranian transmission system is also presented.<<ETX>>","PeriodicalId":6450,"journal":{"name":"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials","volume":"15 1","pages":"331-334 vol.1"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPADM.1991.172065","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Iranian isokeraunic map developed by the authors is presented. A statistical analysis of tower footing resistances of 400 kV lines in the Iranian national grid is also presented. An attempt has been made to evaluate lightning fifty-percent breakdown voltage (V/sub 50/) across 400 kV insulators in Iran, according to obtained keraunic levels and probabilistic results of tower footing resistances. A comparison between calculated V/sub 50/ and V/sub 50/ of presently installed insulators of 400 kV lines in the Iranian transmission system is also presented.<>
伊朗400kv输电线路绝缘子50%击穿电压的评估
介绍了作者绘制的伊朗等地地图。对伊朗国家电网400kv线路塔底电阻进行了统计分析。根据获得的keraunic水平和塔基电阻的概率结果,已经尝试评估伊朗400 kV绝缘子的闪电50%击穿电压(V/sub 50/)。文中还比较了伊朗输电系统中现有400 kV线路绝缘子的V/sub 50/计算值和V/sub 50/计算值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信