Dynamic arc model of the flashover of the polluted insulators

S. Bessedik, H. Hadi
{"title":"Dynamic arc model of the flashover of the polluted insulators","authors":"S. Bessedik, H. Hadi","doi":"10.1109/CEIDP.2011.6232716","DOIUrl":null,"url":null,"abstract":"The importance of the research on insulator pollution has been increased considerably with the rise of the voltage of transmission lines. In order to determine the flashover behavior of polluted high voltage insulators and to identify to physical mechanisms that govern this phenomenon, the researchers have been brought to establish a modeling. In this study after presenting the theoretical and experimental open model, a dynamic arc model has been developed to calculate the flashover. The validity of the model was verified by comparing the computed results with the experimental results of previous researchers and good correlation has been shown.","PeriodicalId":6317,"journal":{"name":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"27 1","pages":"550-554"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2011.6232716","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

The importance of the research on insulator pollution has been increased considerably with the rise of the voltage of transmission lines. In order to determine the flashover behavior of polluted high voltage insulators and to identify to physical mechanisms that govern this phenomenon, the researchers have been brought to establish a modeling. In this study after presenting the theoretical and experimental open model, a dynamic arc model has been developed to calculate the flashover. The validity of the model was verified by comparing the computed results with the experimental results of previous researchers and good correlation has been shown.
污绝缘子闪络的动态电弧模型
随着输电线路电压的升高,对绝缘子污染问题的研究日益重要。为了确定污染高压绝缘子的闪络行为,并确定控制这一现象的物理机制,研究人员建立了一个模型。本文在提出理论和实验开放模型的基础上,建立了计算闪络的动态电弧模型。将计算结果与前人的实验结果进行比较,验证了模型的有效性,并显示出良好的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信