A Field Evaluation of Mandelic Acid in Urine as a Compliance Monitor for Styrene Exposure

J. Bowman, J. Held
{"title":"A Field Evaluation of Mandelic Acid in Urine as a Compliance Monitor for Styrene Exposure","authors":"J. Bowman, J. Held","doi":"10.1080/1047322X.1990.10389687","DOIUrl":null,"url":null,"abstract":"Abstract The Special Studies Unit of Cal/OSHA monitored mandelic acid in urine and styrene exposure in a survey of 324 workers in the fiberglass-reinforced plastics industry. The urine was sampled at the end of the shift, and the mandelic acid was analyzed by high-performance liquid chromatography. A stepwise regression analysis shows that the mandelic acid (MA) concentration is affected by the styrene concentration, the urine's specific gravity, effective respirator usage, work rate, and sampling on Friday; it is unaffected by skin exposure to styrene or exposure to other solvents. The regression model supports the Biological Exposure Index (BEI) of 1 g/L if the MA concentration is standardized for specific gravity. In a comparison of styrene and MA compliance decision, 7 percent of the subjects were false positives, i.e., violating the BEI while in compliance with the styrene threshold limit value. Since one of the false positives was using an organic vapor respirator, the MA monitoring did demonstrate ...","PeriodicalId":8182,"journal":{"name":"Applied occupational and environmental hygiene","volume":"15 1","pages":"526-535"},"PeriodicalIF":0.0000,"publicationDate":"2011-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied occupational and environmental hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/1047322X.1990.10389687","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract The Special Studies Unit of Cal/OSHA monitored mandelic acid in urine and styrene exposure in a survey of 324 workers in the fiberglass-reinforced plastics industry. The urine was sampled at the end of the shift, and the mandelic acid was analyzed by high-performance liquid chromatography. A stepwise regression analysis shows that the mandelic acid (MA) concentration is affected by the styrene concentration, the urine's specific gravity, effective respirator usage, work rate, and sampling on Friday; it is unaffected by skin exposure to styrene or exposure to other solvents. The regression model supports the Biological Exposure Index (BEI) of 1 g/L if the MA concentration is standardized for specific gravity. In a comparison of styrene and MA compliance decision, 7 percent of the subjects were false positives, i.e., violating the BEI while in compliance with the styrene threshold limit value. Since one of the false positives was using an organic vapor respirator, the MA monitoring did demonstrate ...
苯乙烯暴露依从性监测尿液中苯乙醛酸的现场评价
Cal/OSHA特别研究小组对324名玻璃纤维增强塑料行业工人的尿中扁豆酸和苯乙烯暴露进行了监测。换班结束时取尿样,用高效液相色谱法分析扁桃酸。逐步回归分析表明,苯乙烯浓度、尿液比重、有效呼吸器使用率、工作速率和周五采样对曼德酸(MA)浓度有影响;它不受皮肤暴露于苯乙烯或暴露于其他溶剂的影响。如果MA浓度按比重标准化,回归模型支持1 g/L的生物暴露指数(BEI)。在苯乙烯和MA依从性决策的比较中,有7%的受试者是假阳性,即在符合苯乙烯阈值的情况下违反BEI。由于其中一名假阳性患者使用了有机蒸汽呼吸器,MA监测确实显示…
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信