{"title":"Nitrogen Soft X-Ray Yield Optimization from UNU/ICTP PFF Plasma Focus Device","authors":"W. Sahyouni, Alaa Nassif","doi":"10.11648/J.AJMP.20190806.12","DOIUrl":null,"url":null,"abstract":"The aim of this research studying soft x-ray emission from United Nations University/International Centre for Theoretical Physics Plasma Fusion Facility (UNU/ICTP PFF) plasma focus device with nitrogen gas pressure changes and find the maximum value of soft x-ray yield by using the standard parameters of device and do optimization to obtain the combination of pressure and electrodes dimensions that gives the maximum value of soft x-ray yield. Many numerical experiments were carried out using Lee code and obtained the maximum value of soft x-ray yield 0.193J at pressure 1.9 Torr by using the standard parameters of device. We optimized the device and found the optimum combination of pressure and electrode dimensions (P0 = 0.5 Torr, z0 = 9 cm, a = 3.19 cm, b = 3.2 cm,) that gives the maximum value of soft x-ray yield Ysxr = 2.7 J without changing the energy of the device.","PeriodicalId":7717,"journal":{"name":"American Journal of Modern Physics","volume":"80 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Modern Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11648/J.AJMP.20190806.12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The aim of this research studying soft x-ray emission from United Nations University/International Centre for Theoretical Physics Plasma Fusion Facility (UNU/ICTP PFF) plasma focus device with nitrogen gas pressure changes and find the maximum value of soft x-ray yield by using the standard parameters of device and do optimization to obtain the combination of pressure and electrodes dimensions that gives the maximum value of soft x-ray yield. Many numerical experiments were carried out using Lee code and obtained the maximum value of soft x-ray yield 0.193J at pressure 1.9 Torr by using the standard parameters of device. We optimized the device and found the optimum combination of pressure and electrode dimensions (P0 = 0.5 Torr, z0 = 9 cm, a = 3.19 cm, b = 3.2 cm,) that gives the maximum value of soft x-ray yield Ysxr = 2.7 J without changing the energy of the device.