{"title":"Application of Flow Injection Analysis to Analyzing Precipitation/Coprecipitation Behavior of Chromium in Wastewater","authors":"Takemoto Suguru, Kagaya Shigehiro","doi":"10.11190/JER.17.125","DOIUrl":null,"url":null,"abstract":"A flow injection analysis based on spectrophotometry using diphenylcarbazide (FIA-DPC) was applied to the determination of Cr(VI) and total Cr (T-Cr) in order to understand the precipitation and coprecipitation behavior of Cr(III,VI) in wastewater. When 0.5 m of reaction coil, 100 μL of sample loop, and 1.2 mL/min of flow rate of carrier and reagent solutions were used, 10 μg/L 3 mg/L of Cr(VI) could be determined. The limits of detection and quantification were 1.1 and 3.6 μg/L, respectively. T-Cr could also be determined by combining pre-oxidation with permanganate. The precipitation/coprecipitation behavior of Cr(III,VI) obtained by using the FIA-DPC method was almost the same as the theoretical one, indicating that the method is applicable to analyze the behavior of Cr in wastewater.","PeriodicalId":15612,"journal":{"name":"Journal of ecotechnology research","volume":"30 1","pages":"125-129"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of ecotechnology research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11190/JER.17.125","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A flow injection analysis based on spectrophotometry using diphenylcarbazide (FIA-DPC) was applied to the determination of Cr(VI) and total Cr (T-Cr) in order to understand the precipitation and coprecipitation behavior of Cr(III,VI) in wastewater. When 0.5 m of reaction coil, 100 μL of sample loop, and 1.2 mL/min of flow rate of carrier and reagent solutions were used, 10 μg/L 3 mg/L of Cr(VI) could be determined. The limits of detection and quantification were 1.1 and 3.6 μg/L, respectively. T-Cr could also be determined by combining pre-oxidation with permanganate. The precipitation/coprecipitation behavior of Cr(III,VI) obtained by using the FIA-DPC method was almost the same as the theoretical one, indicating that the method is applicable to analyze the behavior of Cr in wastewater.
流动注射分析法在分析废水中铬沉淀/共沉淀行为中的应用
为了了解废水中Cr(III,VI)的沉淀和共沉淀行为,采用分光光度法(FIA-DPC)流动注射法测定了Cr(VI)和总Cr(T-Cr)。在反应线圈直径0.5 m、样品环径100 μL、载体和试剂溶液流速1.2 mL/min的条件下,可测定Cr(VI)浓度为10 μg/L、3 mg/L。检测限和定量限分别为1.1和3.6 μg/L。T-Cr也可以用高锰酸盐联合预氧化法测定。采用FIA-DPC方法得到的Cr(III,VI)的沉淀/共沉淀行为与理论结果基本一致,表明该方法适用于分析Cr在废水中的行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信