{"title":"Application of Flow Injection Analysis to Analyzing Precipitation/Coprecipitation Behavior of Chromium in Wastewater","authors":"Takemoto Suguru, Kagaya Shigehiro","doi":"10.11190/JER.17.125","DOIUrl":null,"url":null,"abstract":"A flow injection analysis based on spectrophotometry using diphenylcarbazide (FIA-DPC) was applied to the determination of Cr(VI) and total Cr (T-Cr) in order to understand the precipitation and coprecipitation behavior of Cr(III,VI) in wastewater. When 0.5 m of reaction coil, 100 μL of sample loop, and 1.2 mL/min of flow rate of carrier and reagent solutions were used, 10 μg/L 3 mg/L of Cr(VI) could be determined. The limits of detection and quantification were 1.1 and 3.6 μg/L, respectively. T-Cr could also be determined by combining pre-oxidation with permanganate. The precipitation/coprecipitation behavior of Cr(III,VI) obtained by using the FIA-DPC method was almost the same as the theoretical one, indicating that the method is applicable to analyze the behavior of Cr in wastewater.","PeriodicalId":15612,"journal":{"name":"Journal of ecotechnology research","volume":"30 1","pages":"125-129"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of ecotechnology research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11190/JER.17.125","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A flow injection analysis based on spectrophotometry using diphenylcarbazide (FIA-DPC) was applied to the determination of Cr(VI) and total Cr (T-Cr) in order to understand the precipitation and coprecipitation behavior of Cr(III,VI) in wastewater. When 0.5 m of reaction coil, 100 μL of sample loop, and 1.2 mL/min of flow rate of carrier and reagent solutions were used, 10 μg/L 3 mg/L of Cr(VI) could be determined. The limits of detection and quantification were 1.1 and 3.6 μg/L, respectively. T-Cr could also be determined by combining pre-oxidation with permanganate. The precipitation/coprecipitation behavior of Cr(III,VI) obtained by using the FIA-DPC method was almost the same as the theoretical one, indicating that the method is applicable to analyze the behavior of Cr in wastewater.