Evaluation of the Effect of Cavity Preparation Using Er,Cr:YSGG Laser on Microleakage of Class V Composite Restorations

Z. Khamverdi, L. Rezaei-Soufi, Hamidreza Haseli Paik, Puya Jabari, M. Ahmadian
{"title":"Evaluation of the Effect of Cavity Preparation Using Er,Cr:YSGG Laser on Microleakage of Class V Composite Restorations","authors":"Z. Khamverdi, L. Rezaei-Soufi, Hamidreza Haseli Paik, Puya Jabari, M. Ahmadian","doi":"10.34172/ajdr.2021.16","DOIUrl":null,"url":null,"abstract":"Background: The application of laser in dentistry for medical purposes such as caries removal, preparation of restorative cavities, and dental surface treatment for more effective bonding of restorative materials to the tooth has been significant. The present experimental study aimed to evaluate the effect of cavity preparation on microleakage by using erbium, chromium-doped yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) lasers, and to compare it with the effect of bur on microleakage in class V composite restorations. Methods: In this experimental study, 20 intact human premolar teeth were randomly divided into 2 equal groups according to the cavity preparation technique: G1: laser cavity preparation (LCP) using a Er,Cr:YSGG laser (Bio Lase, USA), and G2: bur cavity preparation (BCP). Standard class V cavity was prepared on both lingual and buccal surfaces in two groups. The samples underwent thermocycling for 3000 times (5-55ºC) and were immersed in a methylene blue 2% solution for 24 hours. After buccolingual sectioning from the middle of the restoration, a stereomicroscope with 20 x magnification was used to measure the penetration rate of the dye and to determine the score for microleakage. Data were analyzed using SPSS (version 16) software and Mann-Whitney U test (α=5%). Results: According to the study results, the minimum and maximum microleakage values were observed in the occlusal and gingival margins, respectively, which were identically for both groups. Comparing two groups (BCP and LCP) revealed that there was no significant difference between them in terms of microleakage values at the occlusal and gingival margins (P>0.05). Conclusions: It was concluded that cavity preparation using Er,cr:YSGG laser had microleakage values similar to those found with conventional cavity preparation (bur) method in class V composite restorations.","PeriodicalId":8679,"journal":{"name":"Avicenna Journal of Dental Research","volume":"43 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Avicenna Journal of Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/ajdr.2021.16","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The application of laser in dentistry for medical purposes such as caries removal, preparation of restorative cavities, and dental surface treatment for more effective bonding of restorative materials to the tooth has been significant. The present experimental study aimed to evaluate the effect of cavity preparation on microleakage by using erbium, chromium-doped yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) lasers, and to compare it with the effect of bur on microleakage in class V composite restorations. Methods: In this experimental study, 20 intact human premolar teeth were randomly divided into 2 equal groups according to the cavity preparation technique: G1: laser cavity preparation (LCP) using a Er,Cr:YSGG laser (Bio Lase, USA), and G2: bur cavity preparation (BCP). Standard class V cavity was prepared on both lingual and buccal surfaces in two groups. The samples underwent thermocycling for 3000 times (5-55ºC) and were immersed in a methylene blue 2% solution for 24 hours. After buccolingual sectioning from the middle of the restoration, a stereomicroscope with 20 x magnification was used to measure the penetration rate of the dye and to determine the score for microleakage. Data were analyzed using SPSS (version 16) software and Mann-Whitney U test (α=5%). Results: According to the study results, the minimum and maximum microleakage values were observed in the occlusal and gingival margins, respectively, which were identically for both groups. Comparing two groups (BCP and LCP) revealed that there was no significant difference between them in terms of microleakage values at the occlusal and gingival margins (P>0.05). Conclusions: It was concluded that cavity preparation using Er,cr:YSGG laser had microleakage values similar to those found with conventional cavity preparation (bur) method in class V composite restorations.
Er,Cr:YSGG激光制备腔体对V类复合修复体微泄漏影响的评价
背景:激光在牙科中的应用具有重要的医学意义,如龋齿的清除,修复腔的制备以及牙表面处理以更有效地将修复材料与牙齿结合。本实验研究利用掺铒、铬的钇、钪、镓和石榴石(Er,Cr:YSGG)激光器制备腔体对微漏的影响,并与bur对V类复合修复体微漏的影响进行比较。方法:将20颗完整的人前磨牙按造腔技术随机分为2组:G1组:激光造腔(LCP),采用Er,Cr:YSGG激光器(美国Bio Lase公司),G2组:盲牙造腔(BCP)。两组均在舌面和颊面制备标准V类空腔。样品进行3000次热循环(5-55ºC),并在2%亚甲基蓝溶液中浸泡24小时。从修复体中段对舌部进行切片后,使用20倍放大的体视显微镜测量染料的渗透速率并确定微渗漏评分。数据分析采用SPSS (version 16)软件,采用Mann-Whitney U检验(α=5%)。结果:根据研究结果,两组牙合缘和龈缘的最小微漏值和最大微漏值相同。BCP组与LCP组比较,两组牙合龈缘微漏值差异无统计学意义(P>0.05)。结论:在V类复合修复体中,Er,cr:YSGG激光制备腔体的微漏值与常规腔体制备(bur)方法相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信