Effect of AEA-SP Dosage Sequence on Air Entrainment in FA Concrete

IF 0.7 Q4 CONSTRUCTION & BUILDING TECHNOLOGY
A. Shpak, S. Jacobsen
{"title":"Effect of AEA-SP Dosage Sequence on Air Entrainment in FA Concrete","authors":"A. Shpak, S. Jacobsen","doi":"10.2478/ncr-2019-0013","DOIUrl":null,"url":null,"abstract":"Abstract Laboratory measurements show that varying the dosage sequence of air-entraining agent and co-polymer in the mix (SP added before, after or together with AEA) greatly affects air entrainment in fresh and hardened fly ash concrete. Image analysis shows a somewhat lower specific surface when SP is added together with AEA. Foam Index measurements on the same binder materials, admixtures, and dosage sequences were therefore found less useful for studying the effect of admixture combinations. Obtaining a certain air content using the experience with AEA-SP dosage was found to be an untrivial task if there is a lack of parameter control. Finally, examples of successful mixing procedure for air entrainment in a series of high-volume fly ash concrete are shown.","PeriodicalId":42762,"journal":{"name":"Nordic Concrete Research","volume":"104 1","pages":"1 - 21"},"PeriodicalIF":0.7000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nordic Concrete Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/ncr-2019-0013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Laboratory measurements show that varying the dosage sequence of air-entraining agent and co-polymer in the mix (SP added before, after or together with AEA) greatly affects air entrainment in fresh and hardened fly ash concrete. Image analysis shows a somewhat lower specific surface when SP is added together with AEA. Foam Index measurements on the same binder materials, admixtures, and dosage sequences were therefore found less useful for studying the effect of admixture combinations. Obtaining a certain air content using the experience with AEA-SP dosage was found to be an untrivial task if there is a lack of parameter control. Finally, examples of successful mixing procedure for air entrainment in a series of high-volume fly ash concrete are shown.
AEA-SP掺量顺序对FA混凝土掺气性能的影响
摘要实验结果表明,不同掺量的引气剂和共聚物(SP在AEA掺前、掺后或与AEA掺后)对粉煤灰混凝土的掺量有较大影响。图像分析显示,SP与AEA加在一起时,比表面积有所降低。因此,在相同的粘结材料、外加剂和剂量序列上的泡沫指数测量对于研究外加剂组合的影响用处不大。在缺乏参数控制的情况下,利用AEA-SP剂量的经验获得一定的空气含量是一项不平凡的任务。最后,给出了在一系列高掺量粉煤灰混凝土中成功的掺气过程的实例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Nordic Concrete Research
Nordic Concrete Research CONSTRUCTION & BUILDING TECHNOLOGY-
自引率
20.00%
发文量
8
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信