Oclusão Percutânea da Persistência do Ducto Arterioso

Julian Rathke, H. S. Menezes, Raul Ivo Rossi-Filho, J. L. Manica
{"title":"Oclusão Percutânea da Persistência do Ducto Arterioso","authors":"Julian Rathke, H. S. Menezes, Raul Ivo Rossi-Filho, J. L. Manica","doi":"10.1590/0104-1843000000061","DOIUrl":null,"url":null,"abstract":"Background: Patent ductus arteriosus is a congenital condition with high morbidity, especially in preterm infants of extremely low birth weight, representing 5% to 10% of congenital heart diseases. Our objective was to describe the approaches used at a reference hospital for the percutaneous occlusion of PDA. Methods: We conducted a retrospective study on the transcatheter treatment of patent ductus arteriosus from April of 2008 to April of 2010. Results: Forty-seven cases were reviewed and most of them (78.8%) were treated with FlipperTM coils while the remaining patients received the AmplatzerTM device. Ductal morphological configuration was Krichenko type A in 89.4% (34 in the FlipperTM coil group and 8 in the AmplatzerTM group), type D in 6.4% (2 in the FlipperTM coil group and 1 in the AmplatzerTM group) and type E in 4.2% (1 in each group) of patients. Pre-catheterization minimum diameters were 2.6 ± 0.8 mm and 3.8 ± 1.6 mm for the FlipperTM coil and AmplatzerTM groups, respectively. Immediate total occlusion of the defect was obtained in the control angiography in 72.3% of the patients. Seven patients treated with the FlipperTM coil received additional coils and two patients treated with the AmplatzerTM device presented minimal residual shunts. There were no procedure-related complications. In the follow-up after hospital discharge, one patient presented minimal residual shunt at the echography, 45 days after catheterization. Conclusions: Percutaneous patent ductus arteriosus occlusion has proven to be safe and effective in most cases.","PeriodicalId":101093,"journal":{"name":"Revista Brasileira de Cardiologia Invasiva","volume":"93 1","pages":"364-368"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira de Cardiologia Invasiva","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/0104-1843000000061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Patent ductus arteriosus is a congenital condition with high morbidity, especially in preterm infants of extremely low birth weight, representing 5% to 10% of congenital heart diseases. Our objective was to describe the approaches used at a reference hospital for the percutaneous occlusion of PDA. Methods: We conducted a retrospective study on the transcatheter treatment of patent ductus arteriosus from April of 2008 to April of 2010. Results: Forty-seven cases were reviewed and most of them (78.8%) were treated with FlipperTM coils while the remaining patients received the AmplatzerTM device. Ductal morphological configuration was Krichenko type A in 89.4% (34 in the FlipperTM coil group and 8 in the AmplatzerTM group), type D in 6.4% (2 in the FlipperTM coil group and 1 in the AmplatzerTM group) and type E in 4.2% (1 in each group) of patients. Pre-catheterization minimum diameters were 2.6 ± 0.8 mm and 3.8 ± 1.6 mm for the FlipperTM coil and AmplatzerTM groups, respectively. Immediate total occlusion of the defect was obtained in the control angiography in 72.3% of the patients. Seven patients treated with the FlipperTM coil received additional coils and two patients treated with the AmplatzerTM device presented minimal residual shunts. There were no procedure-related complications. In the follow-up after hospital discharge, one patient presented minimal residual shunt at the echography, 45 days after catheterization. Conclusions: Percutaneous patent ductus arteriosus occlusion has proven to be safe and effective in most cases.
经皮闭塞持续动脉导管
背景:动脉导管未闭是一种高发病率的先天性疾病,特别是在极低出生体重的早产儿中,占先天性心脏病的5% ~ 10%。我们的目的是描述在一家参考医院用于经皮PDA闭塞的入路。方法:回顾性分析2008年4月至2010年4月经导管治疗动脉导管未闭的病例。结果:47例患者采用FlipperTM线圈治疗,78.8%的患者采用AmplatzerTM装置治疗。导管形态形态为Krichenko A型占89.4% (FlipperTM线圈组34例,AmplatzerTM组8例),D型占6.4% (FlipperTM线圈组2例,AmplatzerTM组1例),E型占4.2%(每组1例)。FlipperTM线圈组和AmplatzerTM组插管前最小直径分别为2.6±0.8 mm和3.8±1.6 mm。在对照血管造影中,72.3%的患者获得缺损立即完全闭塞。7名使用FlipperTM线圈治疗的患者接受了额外的线圈治疗,2名使用AmplatzerTM装置治疗的患者出现了最小残留分流。无手术相关并发症。在出院后的随访中,1例患者在置管后45天的超声检查中出现最小残留分流。结论:经皮动脉导管未闭闭塞术在大多数情况下是安全有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信