{"title":"Non Contact Vibration Measurements on Parabolic Surface Antenna","authors":"D. Simoiu, L. Bereteu","doi":"10.1515/awutp-2015-0109","DOIUrl":null,"url":null,"abstract":"Abstract In this paper it is present a non contact method for 3D measurements on parabolic surface antenna. In order to obtain modal parameters and modal shapes of a parabolic surface antenna a Microflown USP (Ultimate Sound Probe) is used. Microflown sensors are close to antenna and can be used for the non contact measurement of the normal component of the structural velocity.","PeriodicalId":31012,"journal":{"name":"Annals of West University of Timisoara Physics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of West University of Timisoara Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/awutp-2015-0109","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract In this paper it is present a non contact method for 3D measurements on parabolic surface antenna. In order to obtain modal parameters and modal shapes of a parabolic surface antenna a Microflown USP (Ultimate Sound Probe) is used. Microflown sensors are close to antenna and can be used for the non contact measurement of the normal component of the structural velocity.