Forces Exerted by Hydraulic Cattle Chutes

L. Perino, D. B. Parker, R. Brown, M. Jeter
{"title":"Forces Exerted by Hydraulic Cattle Chutes","authors":"L. Perino, D. B. Parker, R. Brown, M. Jeter","doi":"10.21423/bovine-vol34no1p63-65","DOIUrl":null,"url":null,"abstract":"To describe the magnitude and variability of forces generated, we measured peak forces at nine different locations in hydraulic chutes used for cattle restraint. The headgate, middle of the chute, and tailgate were each measured at 18, 34, and 48 inches from the chute floor using a 3,000 lb capacity, high accuracy S-beam load cell. Peak forces generated by hydraulic chutes ranged from a low of approximately 100 lb to a high of over 3000 lb. There were large variations in forces observed within and between facilities, with the coefficient of variation on chute forces across all chutes at approximately 50% for all positions assessed. At 34 inches from the floor, 43, 14, and 29% of chutes generated less than 600 lb of force at the headgate, middle, and tailgate, respectively, while 29, 50 and 21 % of chutes generated greater than 1000 lb of force at the headgate, middle, and tailgate, respectively. There is a large amount of variability in forces generated by hydraulic chutes used for cattle restraint. Some chutes generate forces potentially hazardous to cattle.","PeriodicalId":22281,"journal":{"name":"The Bovine practitioner","volume":"34 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Bovine practitioner","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21423/bovine-vol34no1p63-65","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To describe the magnitude and variability of forces generated, we measured peak forces at nine different locations in hydraulic chutes used for cattle restraint. The headgate, middle of the chute, and tailgate were each measured at 18, 34, and 48 inches from the chute floor using a 3,000 lb capacity, high accuracy S-beam load cell. Peak forces generated by hydraulic chutes ranged from a low of approximately 100 lb to a high of over 3000 lb. There were large variations in forces observed within and between facilities, with the coefficient of variation on chute forces across all chutes at approximately 50% for all positions assessed. At 34 inches from the floor, 43, 14, and 29% of chutes generated less than 600 lb of force at the headgate, middle, and tailgate, respectively, while 29, 50 and 21 % of chutes generated greater than 1000 lb of force at the headgate, middle, and tailgate, respectively. There is a large amount of variability in forces generated by hydraulic chutes used for cattle restraint. Some chutes generate forces potentially hazardous to cattle.
液压滑槽施加的力
为了描述所产生的力的大小和可变性,我们测量了用于牛约束的液压滑槽中九个不同位置的峰值力。使用3000磅容量的高精度s梁测力元件,分别测量了滑道的前闸、中间闸和尾闸距滑道地面18英寸、34英寸和48英寸的位置。液压滑槽产生的峰值力从大约100磅到超过3000磅不等。在设施内部和设施之间观察到的力变化很大,所有滑槽的力变化系数在所有评估位置上约为50%。在距地面34英寸处,43%、14%和29%的滑道分别在前闸、中闸和后闸处产生小于600磅的力,而29%、50%和21%的滑道分别在前闸、中闸和后闸处产生大于1000磅的力。用于牲畜约束的液压滑槽所产生的力有很大的可变性。有些滑道会产生对牛有潜在危险的力量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信