TRI-PICCS in single source and dual source CT

C. Maas, C. Hofmann, M. Kachelries
{"title":"TRI-PICCS in single source and dual source CT","authors":"C. Maas, C. Hofmann, M. Kachelries","doi":"10.1109/NSSMIC.2010.5874304","DOIUrl":null,"url":null,"abstract":"Recently, temporal resolution improved prior image constrained compressed sensing (TRI-PICCS), an algorithm promising improved temporal resolution in cardiac CT, was proposed. Here, we extend the ideas to dual source CT. Single source and dual source CT simulations of a heart phantom as well as a single source cardiac CT measurement are used to evaluate the temporal resolution of CT images reconstructed with TRI-PICCS. Short scan reconstructions of the same data are used for comparison. The result of this study is that there seems to be an advantage in temporal resolution when using TRI-PICCS, however, this impression is actually caused by a slight shift of the motion phase when using TRI-PICCS. Comparing short scan reconstructions and TRI-PICCS reconstructions at the same motion phase, no temporal resolution improvement could be confirmed.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"22 1","pages":"2805-2810"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2010.5874304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Recently, temporal resolution improved prior image constrained compressed sensing (TRI-PICCS), an algorithm promising improved temporal resolution in cardiac CT, was proposed. Here, we extend the ideas to dual source CT. Single source and dual source CT simulations of a heart phantom as well as a single source cardiac CT measurement are used to evaluate the temporal resolution of CT images reconstructed with TRI-PICCS. Short scan reconstructions of the same data are used for comparison. The result of this study is that there seems to be an advantage in temporal resolution when using TRI-PICCS, however, this impression is actually caused by a slight shift of the motion phase when using TRI-PICCS. Comparing short scan reconstructions and TRI-PICCS reconstructions at the same motion phase, no temporal resolution improvement could be confirmed.
单源和双源CT的三piccs
最近提出了一种时间分辨率改进的先验图像约束压缩感知(TRI-PICCS)算法,该算法有望提高心脏CT的时间分辨率。在这里,我们将思想扩展到双源CT。利用单源和双源CT模拟心脏幻影以及单源CT测量来评估TRI-PICCS重建的CT图像的时间分辨率。同一数据的短扫描重建用于比较。本研究的结果是,当使用TRI-PICCS时,在时间分辨率上似乎有优势,然而,这种印象实际上是由使用TRI-PICCS时运动相位的轻微移动引起的。在同一运动阶段,短扫描重建与TRI-PICCS重建相比,没有时间分辨率的提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信