Separation and determination of lead in human urine and water samples based on thiol functionalized mesoporous silica nanoparticles packed on cartridges by micro column fast micro solid-phase extraction

M. Gou, Baharak Bahrami Yarahmadi
{"title":"Separation and determination of lead in human urine and water samples based on thiol functionalized mesoporous silica nanoparticles packed on cartridges by micro column fast micro solid-phase extraction","authors":"M. Gou, Baharak Bahrami Yarahmadi","doi":"10.24200/amecj.v2.i03.72","DOIUrl":null,"url":null,"abstract":"An efficient method based on thiol functionalized mesoporous silica nanoparticles (HS-MSNPs) was used for extraction of lead ions (PbII) from urine and water samples by packed column micro solid phase extraction (PC-MSPE). By procedure, 15 mg of HS-MSNPs packed in syringe cartridges (SC, 5 mL) with cellulose membrane and pH adjusting at 5.5-6.5.  Then, the lead of urine and water sample was efficiently extracted on HS-MSNPs after pushing the plunger of a syringe. Finally, the Pb (II) was back-extracted with inorganic acid solution and the remained solution determined by electrothermal atomic absorption spectrometry (ET-AAS). By optimization conditions, the enrichment factor, LOD, linear range and RSD% was obtained 24.8, 0.04 μg L-1, 0.12-5.5 μg L-1 and less than 5%, respectively for 5 mL of urine samples. The validation was confirmed by spiking of real samples and using certified reference material (CRM, NIST) in water and urine sample.","PeriodicalId":7797,"journal":{"name":"Analytical Methods in Environmental Chemistry Journal","volume":"394 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods in Environmental Chemistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24200/amecj.v2.i03.72","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

An efficient method based on thiol functionalized mesoporous silica nanoparticles (HS-MSNPs) was used for extraction of lead ions (PbII) from urine and water samples by packed column micro solid phase extraction (PC-MSPE). By procedure, 15 mg of HS-MSNPs packed in syringe cartridges (SC, 5 mL) with cellulose membrane and pH adjusting at 5.5-6.5.  Then, the lead of urine and water sample was efficiently extracted on HS-MSNPs after pushing the plunger of a syringe. Finally, the Pb (II) was back-extracted with inorganic acid solution and the remained solution determined by electrothermal atomic absorption spectrometry (ET-AAS). By optimization conditions, the enrichment factor, LOD, linear range and RSD% was obtained 24.8, 0.04 μg L-1, 0.12-5.5 μg L-1 and less than 5%, respectively for 5 mL of urine samples. The validation was confirmed by spiking of real samples and using certified reference material (CRM, NIST) in water and urine sample.
微柱快速微固相萃取-巯基化介孔二氧化硅纳米颗粒填料填料分离测定人体尿液和水中的铅
采用巯基功能化介孔二氧化硅纳米颗粒(HS-MSNPs)作为填料柱微固相萃取(PC-MSPE)提取尿、水样中的铅离子(PbII)。将15mg hs - msnp装入注射器盒(SC, 5ml)中,用纤维素膜包装,pH调节在5.5-6.5。然后,推注射器的柱塞,在hs - msnp上有效地提取尿和水样中的铅。最后用无机酸溶液反提Pb (II),剩余溶液用电热原子吸收光谱法(ET-AAS)测定。通过优化条件,5 mL尿样的富集因子为24.8,LOD为0.04 μg -1,线性范围为0.12 ~ 5.5 μg -1, RSD% < 5%。通过在水和尿样中使用经认证的标准物质(CRM, NIST)对真实样品进行峰化验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信