{"title":"A note on controlling the optical density on analog film records in strong motion accelerographs","authors":"M.D. Trifunac,&nbsp;D.K. Marcus,&nbsp;K. Moslem","doi":"10.1016/0261-7277(85)90033-6","DOIUrl":null,"url":null,"abstract":"<div><p>A device and its solid state logic are described which improve the uniformity of the optical density of recorded analog traces on film. An example is presented for the Light Control Module LM-8, designed to work in the SMA-1 strong motion accelerograph. Tests have been performed to determine the overall performance of LM-8. The results are very favorable and show that LM-8 improves significantly the overall quality of strong motion acceleration traces recorded on film.</p></div>","PeriodicalId":100715,"journal":{"name":"International Journal of Soil Dynamics and Earthquake Engineering","volume":"4 1","pages":"Pages 31-34"},"PeriodicalIF":0.0000,"publicationDate":"1985-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0261-7277(85)90033-6","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Soil Dynamics and Earthquake Engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0261727785900336","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A device and its solid state logic are described which improve the uniformity of the optical density of recorded analog traces on film. An example is presented for the Light Control Module LM-8, designed to work in the SMA-1 strong motion accelerograph. Tests have been performed to determine the overall performance of LM-8. The results are very favorable and show that LM-8 improves significantly the overall quality of strong motion acceleration traces recorded on film.

关于控制强运动加速度计中模拟胶片记录的光密度的说明
本文描述了一种改善薄膜上记录的模拟走线光密度均匀性的器件及其固态逻辑。介绍了用于SMA-1强运动加速度计的光控模块LM-8的实例。已经进行了测试,以确定LM-8的总体性能。结果非常令人满意,表明LM-8显著提高了胶片上记录的强运动加速度轨迹的整体质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信