Micro-channel device for spectrum measurement using optical fiber aligned with bias spring with reversely tapered profile

H. Iimura, D. Deng, S. Kumagai, Y. Ohishi, M. Sasaki
{"title":"Micro-channel device for spectrum measurement using optical fiber aligned with bias spring with reversely tapered profile","authors":"H. Iimura, D. Deng, S. Kumagai, Y. Ohishi, M. Sasaki","doi":"10.1109/OMN.2013.6659075","DOIUrl":null,"url":null,"abstract":"The micro-channel device for passing the supercontinuum light across the liquid channel is developed. For the accurate alignment of the optical fibers, the bias spring with the reversely tapered profile is newly introduced realizing the high transmission ratio. Infra-red absorption spectrum is measured for obtaining the molecular information. When the water is introduced in the liquid channel, the characteristic absorption peak is clearly confirmed.","PeriodicalId":6334,"journal":{"name":"2013 International Conference on Optical MEMS and Nanophotonics (OMN)","volume":"7 1","pages":"93-94"},"PeriodicalIF":0.0000,"publicationDate":"2013-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Conference on Optical MEMS and Nanophotonics (OMN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OMN.2013.6659075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The micro-channel device for passing the supercontinuum light across the liquid channel is developed. For the accurate alignment of the optical fibers, the bias spring with the reversely tapered profile is newly introduced realizing the high transmission ratio. Infra-red absorption spectrum is measured for obtaining the molecular information. When the water is introduced in the liquid channel, the characteristic absorption peak is clearly confirmed.
用于光谱测量的微通道装置,该装置使用光纤对准具有反向锥形轮廓的偏置弹簧
研制了一种使超连续光通过液体通道的微通道装置。为了实现光纤的精确对准,新引入了反锥型偏置弹簧,实现了高传输率。测量红外吸收光谱以获取分子信息。当液体通道中引入水时,特征吸收峰得到了清晰的确认。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信