{"title":"Determination of Chromium in blood serum using Atomic Absorption Spectrophotometric (AAS)","authors":"Mohammed T. Khathi, A. Q. Abdulwahab, Zainab M. Kareem","doi":"10.32792/utq/utj/vol11/2/8","DOIUrl":null,"url":null,"abstract":"A new approach for the direct determination of chromium by Electrothermal Atomic Absorption spectrometry (ETAAS) is proposed, the method employs a 1.0 cm X 0.3 cm Tantalum metal coil placed in graphite tube. The experimental conditions for the determination of chromium via this method have been optimized. Pyrolysis and atomization curves are constructed using uncoated graphite tube without and with coil. The calibration curves were linear over the rang 10- 50 ng/ml of chromium concentration, with relative standard deviation values, at 0.013, 0.018 and 0.024µg/ml. the accuracy and precision of the method was evaluated by determining recoveries  percentage between (99.7-101) and standard deviation and  using different concentrations of standard solutions of  this method was applied successfully for the determination of  chromium in human blood serum.","PeriodicalId":23465,"journal":{"name":"University of Thi-Qar Journal","volume":"31 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"University of Thi-Qar Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32792/utq/utj/vol11/2/8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A new approach for the direct determination of chromium by Electrothermal Atomic Absorption spectrometry (ETAAS) is proposed, the method employs a 1.0 cm X 0.3 cm Tantalum metal coil placed in graphite tube. The experimental conditions for the determination of chromium via this method have been optimized. Pyrolysis and atomization curves are constructed using uncoated graphite tube without and with coil. The calibration curves were linear over the rang 10- 50 ng/ml of chromium concentration, with relative standard deviation values, at 0.013, 0.018 and 0.024µg/ml. the accuracy and precision of the method was evaluated by determining recoveries  percentage between (99.7-101) and standard deviation and  using different concentrations of standard solutions of  this method was applied successfully for the determination of  chromium in human blood serum.
原子吸收分光光度法测定血清中铬
提出了一种用电热原子吸收光谱法(ETAAS)直接测定铬的新方法,该方法将一个1.0 cm × 0.3 cm的钽金属线圈置于石墨管中。对该方法测定铬的实验条件进行了优化。采用不带线圈和带线圈的无涂层石墨管构建了热解和雾化曲线。在10 ~ 50 ng/ml铬浓度范围内,校正曲线呈线性,相对标准偏差值分别为0.013、0.018和0.024µg/ml。测定回收率在(99.7 ~ 101)和标准偏差之间,评价了该方法的准确度和精密度,并成功地将不同浓度的标准溶液应用于人血清中铬的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信