Mesure du débit du sang de la veine porte au moyen d'un débitmètre électromagnétique chez la chèvre

J. Barry, Elisabeth Debras, J. Lefaivre, C. Champredon
{"title":"Mesure du débit du sang de la veine porte au moyen d'un débitmètre électromagnétique chez la chèvre","authors":"J. Barry, Elisabeth Debras, J. Lefaivre, C. Champredon","doi":"10.1051/RND:19790606","DOIUrl":null,"url":null,"abstract":"Summary. Measurement of portal vein blood flow in goats using an electromagnetic flow- meter. When quantitatively measuring the products of digestion in the portal blood, the following factors are to be studied : - the difference between the concentrations of those products in the arterial blood affe- rent to the alimentary canal and of those in the venous portal blood, - blood flow in the portal vein. As a preliminary step, we have undertaken the study of the continuous measurement of the portal blood flow in ruminants (goats), using a method analogous to that employed by Rérat in pigs. Nine goats were fitted with a ring-probe around the portal vein ; during reading, the probe was attached to an electromagnetic flow-meter connected to a recor-der. Fifteen readings were taken on 4 of the animals (mean live weight : 47 kg) for about 7 hours after the morning feeding. After installation, each gauge allowed readings for 4 to 5 consecutive weeks. The signal then faded, and the animals were slaughtered and exami- ned. As the wall of the portal vein had slightly thickened and therefore its lumen was only slightly reduced, signal damping could be attributed to a change in probe functio- ning. The mean flow, measured at the time of reading, was 1 830 ml/min or 39 ml/min/kg of live weight. This study showed a large variability in the flow and distinguished 3 variations throughout the day :","PeriodicalId":7885,"journal":{"name":"Annales De Biologie Animale Biochimie Biophysique","volume":"142 1","pages":"733-738"},"PeriodicalIF":0.0000,"publicationDate":"1979-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales De Biologie Animale Biochimie Biophysique","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/RND:19790606","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Summary. Measurement of portal vein blood flow in goats using an electromagnetic flow- meter. When quantitatively measuring the products of digestion in the portal blood, the following factors are to be studied : - the difference between the concentrations of those products in the arterial blood affe- rent to the alimentary canal and of those in the venous portal blood, - blood flow in the portal vein. As a preliminary step, we have undertaken the study of the continuous measurement of the portal blood flow in ruminants (goats), using a method analogous to that employed by Rérat in pigs. Nine goats were fitted with a ring-probe around the portal vein ; during reading, the probe was attached to an electromagnetic flow-meter connected to a recor-der. Fifteen readings were taken on 4 of the animals (mean live weight : 47 kg) for about 7 hours after the morning feeding. After installation, each gauge allowed readings for 4 to 5 consecutive weeks. The signal then faded, and the animals were slaughtered and exami- ned. As the wall of the portal vein had slightly thickened and therefore its lumen was only slightly reduced, signal damping could be attributed to a change in probe functio- ning. The mean flow, measured at the time of reading, was 1 830 ml/min or 39 ml/min/kg of live weight. This study showed a large variability in the flow and distinguished 3 variations throughout the day :
用电磁流量计测量山羊门静脉的血流量
总结。用电磁流量计测量山羊门静脉血流。当定量测量门静脉血液中的消化产物时,需要研究以下因素:流向消化道的动脉血中消化产物的浓度与门静脉血液中消化产物的浓度之间的差异;门静脉血流。作为初步步骤,我们已经开展了反刍动物(山羊)门静脉血流连续测量的研究,使用的方法类似于rsamrat在猪身上使用的方法。9只山羊在门静脉周围安装环状探针;读数时,探头连接到与记录仪相连的电磁流量计上。在早上喂食后约7小时内,对其中4只动物(平均活重:47 kg)进行了15次读数。安装后,每个仪表允许连续读数4至5周。然后信号消失了,动物被宰杀并接受检查。由于门静脉壁略有增厚,因此其管腔仅略有减少,信号衰减可归因于探头功能的改变。读数时测量的平均流量为1 830 ml/min或39 ml/min/kg活重。这项研究显示了流量的巨大变化,并在一天中区分了3种变化:
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信