Comparison of Various Root Canal Filling Materials and Obturation Techniques for Primary Teeth Using Microcomputed Tomography

IF 0.6 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
G. Ozturk, M. Aydınbelge, H. Gumus
{"title":"Comparison of Various Root Canal Filling Materials and Obturation Techniques for Primary Teeth Using Microcomputed Tomography","authors":"G. Ozturk, M. Aydınbelge, H. Gumus","doi":"10.1177/23202068211036148","DOIUrl":null,"url":null,"abstract":"Aim: The aim of this study was to compare the effectiveness of different filling materials and obturation techniques for root canal obturation in primary teeth. Materials and Methods: Eighty maxillary primary incisors were included in this in vitro study. After biomechanical preparation, all samples were scanned using microcomputed tomography (micro-CT) and root canal volumes were calculated. Samples were grouped according to filling materials and obturation techniques, with ten samples in each group. The samples were filled with zinc oxide eugenol (ZOE) and Vitapex using four different obturation techniques (local anesthesia syringe, lentulo spiral, pastinject, and lentulo spiral–ultrasonic activation). After filling, samples were scanned a second time using micro-CT and root canal volumes were calculated. The statistical analysis was performed using SPSS version 24.0. Data were analyzed by Kruskal–Wallis and Mann–Whitney U tests. Results: When the ZOE and Vitapex were compared, it was observed that there were no significant differences between their postobturated volumes, percentage obturated volume (POV), internal void (IV), and percentage of internal void volume (PIV) (P > .05). The local anesthesia syringe group had a significantly lower postobturated volume and POV, and a significantly higher IV and PIV for both filling materials than that by the other groups (P < .05). There was no significant difference between the other obturation techniques (P > .05). For the local anesthesia syringe group, postobturated volume and POV were significantly higher and IV and PIV were significantly lower with Vitapex than with ZOE (P < .05). There was no significant difference between the other obturation techniques filled either with ZOE or Vitapex (P > .05). Conclusion: Except for the syringe technique, no difference was observed between the ZOE and Vitapex materials. The syringe technique used in the primary root canal filling was less effective than the other techniques, which had similar efficacy, and in this technique, more effective canal filling was achieved with Vitapex.","PeriodicalId":43017,"journal":{"name":"Journal of Advanced Oral Research","volume":"198 1","pages":"53 - 61"},"PeriodicalIF":0.6000,"publicationDate":"2021-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Oral Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/23202068211036148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The aim of this study was to compare the effectiveness of different filling materials and obturation techniques for root canal obturation in primary teeth. Materials and Methods: Eighty maxillary primary incisors were included in this in vitro study. After biomechanical preparation, all samples were scanned using microcomputed tomography (micro-CT) and root canal volumes were calculated. Samples were grouped according to filling materials and obturation techniques, with ten samples in each group. The samples were filled with zinc oxide eugenol (ZOE) and Vitapex using four different obturation techniques (local anesthesia syringe, lentulo spiral, pastinject, and lentulo spiral–ultrasonic activation). After filling, samples were scanned a second time using micro-CT and root canal volumes were calculated. The statistical analysis was performed using SPSS version 24.0. Data were analyzed by Kruskal–Wallis and Mann–Whitney U tests. Results: When the ZOE and Vitapex were compared, it was observed that there were no significant differences between their postobturated volumes, percentage obturated volume (POV), internal void (IV), and percentage of internal void volume (PIV) (P > .05). The local anesthesia syringe group had a significantly lower postobturated volume and POV, and a significantly higher IV and PIV for both filling materials than that by the other groups (P < .05). There was no significant difference between the other obturation techniques (P > .05). For the local anesthesia syringe group, postobturated volume and POV were significantly higher and IV and PIV were significantly lower with Vitapex than with ZOE (P < .05). There was no significant difference between the other obturation techniques filled either with ZOE or Vitapex (P > .05). Conclusion: Except for the syringe technique, no difference was observed between the ZOE and Vitapex materials. The syringe technique used in the primary root canal filling was less effective than the other techniques, which had similar efficacy, and in this technique, more effective canal filling was achieved with Vitapex.
不同根管充填材料与乳牙充填技术的微计算机断层扫描比较
目的:比较不同充填材料和充填技术对乳牙根管充填的效果。材料与方法:采用80颗上颌一切牙进行体外实验。生物力学准备完成后,使用微计算机断层扫描(micro-CT)对所有样本进行扫描,并计算根管体积。按填充物和封堵技术进行分组,每组10个。采用四种不同的封闭技术(局麻注射器、lentulo螺旋、pastinject和lentulo螺旋-超声激活)填充氧化锌丁香酚(ZOE)和Vitapex。充填后,使用micro-CT对样品进行第二次扫描,计算根管体积。采用SPSS 24.0版本进行统计分析。数据分析采用Kruskal-Wallis和Mann-Whitney U检验。结果:将ZOE与Vitapex进行比较,发现它们的闭孔后容积、闭孔容积百分比(POV)、内腔容积百分比(IV)、内腔容积百分比(PIV)差异无统计学意义(P > 0.05)。局麻注射器组闭合后容积和POV均显著低于其他组,两种填充物的IV和PIV均显著高于其他组(P < 0.05)。其他封闭技术间差异无统计学意义(P > 0.05)。局麻注射器组,Vitapex组闭孔后容积和POV显著高于ZOE组,IV和PIV显著低于ZOE组(P < 0.05)。ZOE充填与Vitapex充填两种充填方式间无显著性差异(P > 0.05)。结论:除了注射技术外,ZOE与Vitapex材料之间无显著差异。使用注射器技术填充主根管的效果不如其他技术,但效果相似,在这种技术中,使用Vitapex可以更有效地填充根管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Advanced Oral Research
Journal of Advanced Oral Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.10
自引率
0.00%
发文量
18
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信