Parameter-less fault locator using synchronized/un-synchronized data for overhead transmission line

Jay Prakash Keshri, H. Tiwari
{"title":"Parameter-less fault locator using synchronized/un-synchronized data for overhead transmission line","authors":"Jay Prakash Keshri, H. Tiwari","doi":"10.1109/COMPTELIX.2017.8003975","DOIUrl":null,"url":null,"abstract":"A new fault location algorithm based upon two end synchronized data for high voltage transmission line is proposed which considers arcing fault calculation. In this work least error square (LES) principal is used without considering the line parameters. The least error square principle is used on positive sequence equivalent circuit to calculate the fault distance from the reference bus. This algorithm is simple to understand and easy to implement. since it is independent of line parameter therefore it can be applied to both lumped and distributed transmission lines. This algorithm provide promising results against the variability in fault resistance on the account of two end data. PSCAD transient program is been used to create fault cases along with MATLAB, which calculate fault location. The results shows the effectiveness of the proposed algorithm.","PeriodicalId":6917,"journal":{"name":"2017 International Conference on Computer, Communications and Electronics (Comptelix)","volume":"518 1","pages":"260-264"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Computer, Communications and Electronics (Comptelix)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COMPTELIX.2017.8003975","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

A new fault location algorithm based upon two end synchronized data for high voltage transmission line is proposed which considers arcing fault calculation. In this work least error square (LES) principal is used without considering the line parameters. The least error square principle is used on positive sequence equivalent circuit to calculate the fault distance from the reference bus. This algorithm is simple to understand and easy to implement. since it is independent of line parameter therefore it can be applied to both lumped and distributed transmission lines. This algorithm provide promising results against the variability in fault resistance on the account of two end data. PSCAD transient program is been used to create fault cases along with MATLAB, which calculate fault location. The results shows the effectiveness of the proposed algorithm.
基于同步/非同步数据的架空输电线路无参数故障定位器
提出了一种考虑电弧故障计算的基于两端同步数据的高压输电线路故障定位算法。本文采用最小误差二乘原理,不考虑线路参数。在正序等效电路中采用最小误差二乘原理来计算与参考母线的故障距离。该算法简单易懂,易于实现。由于它与线路参数无关,因此它既适用于集总输电线路,也适用于分布式输电线路。该算法对两端数据的故障抗力变化具有很好的抑制作用。利用PSCAD暂态程序创建故障案例,并结合MATLAB进行故障定位计算。实验结果表明了该算法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信