Esther Carbó-Laso , Pablo Sanz-Ruiz , Tania Quevedo-Narciso , Luis Quiroga-Montes , Marina Benito-Gallo , Javier Vaquero-Martín
{"title":"Resultados clínicos y funcionales de la artroplastia total de rodilla Low Contact Stress (LCS®) con un mínimo de 5 años de seguimiento","authors":"Esther Carbó-Laso , Pablo Sanz-Ruiz , Tania Quevedo-Narciso , Luis Quiroga-Montes , Marina Benito-Gallo , Javier Vaquero-Martín","doi":"10.1016/j.rslaot.2016.06.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Rotating-platform knee prosthesis were design to reduce contact stress of the implants and to increase the durability of implants.</p></div><div><h3>Objective</h3><p>To report the clinical outcomes of a consecutive series of patients who underwent primary rotating-platform knee arthroplasty, with a mean follow-up of 94 months.</p></div><div><h3>Material and method</h3><p>From 2003 to 2010, 75 total knee replacements were performed with Low Contact Stress (LCS<sup>®</sup>) rotating-platform prosthesis. Painful knee osteoarthritis was the main diagnosis. Mean follow-up was 94 (60-118) months. Preoperatively, 64 knees had varus angulation (mean: 169°) and eleven knees had valgus angulation (mean: 187.8°). Patients were evaluated with the Hospital for Special Surgery (HSS) score at 1, 12, 36 and 60 months postoperatively.</p></div><div><h3>Results</h3><p>Two intraoperative partial patella tendon avulsions (2.6%) were diagnosed. Six knees showed loosening of the tibial component (8%) and four (5.3%) required revision. Two chronic infections (2.6%) were successfully managed. No polyethylene dislocation (spin-out) was observed. The mean preoperative HSS score was 44.6 points, which improved to 86.9 points at the end of the follow-up (<em>P</em> <!--><<!--> <!-->0.001).</p></div><div><h3>Conclusion</h3><p>Our study showed good survivorship and functional results of rotating-platform knee replacement at a mean follow-up of 94 months, similar to results of conventional fixed-bearing TKA.</p></div><div><h3>Level of evidence</h3><p>IV.</p></div>","PeriodicalId":101114,"journal":{"name":"Revista Latinoamericana de Cirugía Ortopédica","volume":"1 1","pages":"Pages 3-8"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.rslaot.2016.06.001","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Latinoamericana de Cirugía Ortopédica","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2444972516300067","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Rotating-platform knee prosthesis were design to reduce contact stress of the implants and to increase the durability of implants.
Objective
To report the clinical outcomes of a consecutive series of patients who underwent primary rotating-platform knee arthroplasty, with a mean follow-up of 94 months.
Material and method
From 2003 to 2010, 75 total knee replacements were performed with Low Contact Stress (LCS®) rotating-platform prosthesis. Painful knee osteoarthritis was the main diagnosis. Mean follow-up was 94 (60-118) months. Preoperatively, 64 knees had varus angulation (mean: 169°) and eleven knees had valgus angulation (mean: 187.8°). Patients were evaluated with the Hospital for Special Surgery (HSS) score at 1, 12, 36 and 60 months postoperatively.
Results
Two intraoperative partial patella tendon avulsions (2.6%) were diagnosed. Six knees showed loosening of the tibial component (8%) and four (5.3%) required revision. Two chronic infections (2.6%) were successfully managed. No polyethylene dislocation (spin-out) was observed. The mean preoperative HSS score was 44.6 points, which improved to 86.9 points at the end of the follow-up (P < 0.001).
Conclusion
Our study showed good survivorship and functional results of rotating-platform knee replacement at a mean follow-up of 94 months, similar to results of conventional fixed-bearing TKA.
设计旋转平台膝关节假体是为了减少假体的接触应力,增加假体的耐用性。目的报道连续接受原发性旋转平台膝关节置换术的患者的临床结果,平均随访94个月。材料与方法自2003年至2010年,采用低接触应力(LCS®)旋转平台假体进行全膝关节置换术75例。疼痛性膝骨关节炎为主要诊断。平均随访94(60-118)个月。术前64膝内翻成角(平均169°),11膝外翻成角(平均187.8°)。分别于术后1个月、12个月、36个月和60个月用特殊外科医院(Hospital for Special Surgery, HSS)评分对患者进行评价。结果术中髌骨部分肌腱撕脱2例(2.6%)。6例膝关节显示胫骨部分松动(8%),4例(5.3%)需要翻修。2例慢性感染(2.6%)得到成功控制。未观察到聚乙烯位错(旋出)。术前HSS评分平均为44.6分,随访结束时提高至86.9分(P <0.001)。结论:我们的研究显示旋转平台膝关节置换术在平均随访94个月后获得了良好的生存率和功能结果,与传统固定轴承TKA的结果相似。证据水平: