{"title":"Fault Location in distribution systems with distributed generation using Support Vector Machines and smart meters","authors":"R. Pérez, C. Vásquez","doi":"10.1109/ETCM.2016.7750857","DOIUrl":null,"url":null,"abstract":"In this paper the fault location is presented in distribution systems with distributed generation using Support Vector Machines and information provided by smart meters located on the system. Different types of faults that can occur in a distribution system are simulated for fault resistances 5 to 30 Ohms in steps of 5 Ohms. Support Vector Machines were trained with effective voltage values measured at the substation in distributed generation and smart meters. The results show that the accuracy in locating all types of failure is higher than 87%, demonstrating a fortress in this tool.","PeriodicalId":6480,"journal":{"name":"2016 IEEE Ecuador Technical Chapters Meeting (ETCM)","volume":"29 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Ecuador Technical Chapters Meeting (ETCM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ETCM.2016.7750857","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

In this paper the fault location is presented in distribution systems with distributed generation using Support Vector Machines and information provided by smart meters located on the system. Different types of faults that can occur in a distribution system are simulated for fault resistances 5 to 30 Ohms in steps of 5 Ohms. Support Vector Machines were trained with effective voltage values measured at the substation in distributed generation and smart meters. The results show that the accuracy in locating all types of failure is higher than 87%, demonstrating a fortress in this tool.
基于支持向量机和智能电表的分布式发电配电系统故障定位
本文利用支持向量机和系统上的智能电表提供的信息对分布式发电配电系统进行故障定位。针对5 ~ 30欧姆的故障电阻,以5欧姆为步长,模拟了配电系统中可能出现的不同类型的故障。利用分布式发电和智能电表中变电站测量的有效电压值对支持向量机进行训练。结果表明,该工具对所有类型故障的定位精度均高于87%,证明了该工具的安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信