Z. Lv, Chen Zhang, Yuntong Ma, Kai Wu, Yonghong Cheng
{"title":"Analysis of the Charge Transport in LDPE with Combined Measurement of Space Charge and Current","authors":"Z. Lv, Chen Zhang, Yuntong Ma, Kai Wu, Yonghong Cheng","doi":"10.1109/ICD46958.2020.9341927","DOIUrl":null,"url":null,"abstract":"Space charge accumulation is an important issue for HVDC cable design. The space charge accumulation are determined by the charge transport property which can be monitored by the space charge and conduction current measurement. In this paper, based on PEA system and three-electrode system, the modified combined measurement system was developed to measure the space charge and current in LDPE samples simultaneously. The results show that the current gradually decreased with the accumulation of homocharges; the generation and movement of space charge packet resulted in the current peaks; the reduction of homocharge accumulation and the increase of heterocharge tends to increase the current.","PeriodicalId":6795,"journal":{"name":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","volume":"55 1","pages":"367-370"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICD46958.2020.9341927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Space charge accumulation is an important issue for HVDC cable design. The space charge accumulation are determined by the charge transport property which can be monitored by the space charge and conduction current measurement. In this paper, based on PEA system and three-electrode system, the modified combined measurement system was developed to measure the space charge and current in LDPE samples simultaneously. The results show that the current gradually decreased with the accumulation of homocharges; the generation and movement of space charge packet resulted in the current peaks; the reduction of homocharge accumulation and the increase of heterocharge tends to increase the current.