Experimental evaluation on SAR around the implanted cardiac pacemaker by mobile phone

Y. Endo, Masaharu Takahashi, K. Ito, K. Saito, Soichi Watanabe
{"title":"Experimental evaluation on SAR around the implanted cardiac pacemaker by mobile phone","authors":"Y. Endo, Masaharu Takahashi, K. Ito, K. Saito, Soichi Watanabe","doi":"10.1145/2093698.2093708","DOIUrl":null,"url":null,"abstract":"Recently, electromagnetic interference (EMI) of an implanted pacemaker with a mobile phone has been investigated. However, there are few studies of specific absorption rate (SAR) around the implanted pacemaker by the mobile phone. In this study, SAR distribution around the pacemaker model embedded into the parallelepiped torso phantom was evaluated experimentally. As a result, characteristic SAR distribution, which is caused by implanted pacemaker, was observed.","PeriodicalId":91990,"journal":{"name":"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2093698.2093708","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Recently, electromagnetic interference (EMI) of an implanted pacemaker with a mobile phone has been investigated. However, there are few studies of specific absorption rate (SAR) around the implanted pacemaker by the mobile phone. In this study, SAR distribution around the pacemaker model embedded into the parallelepiped torso phantom was evaluated experimentally. As a result, characteristic SAR distribution, which is caused by implanted pacemaker, was observed.
手机对植入式心脏起搏器周围SAR的实验评价
最近,研究人员对植入手机的起搏器的电磁干扰进行了研究。然而,关于手机植入起搏器周围的辐射比吸收率(SAR)的研究很少。在本研究中,实验评估了嵌入平行六面体躯干幻体的起搏器模型周围的SAR分布。结果观察到由植入起搏器引起的特征性SAR分布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信