Postoperative Pain and Microbiological Evaluation After Using 810nm Diode Laser Disinfection in Single Rooted Teeth with Necrotic Pulp and Periapical Radiolucency: Randomized Control Clinical Trial

Sabah Sobhy, Mervat I. Fawzy, Hemat M. Elsheikh, M. Abdel-Aziz
{"title":"Postoperative Pain and Microbiological Evaluation After Using 810nm Diode Laser Disinfection in Single Rooted Teeth with Necrotic Pulp and Periapical Radiolucency: Randomized Control Clinical Trial","authors":"Sabah Sobhy, Mervat I. Fawzy, Hemat M. Elsheikh, M. Abdel-Aziz","doi":"10.21608/adjg.2022.98162.1414","DOIUrl":null,"url":null,"abstract":"Purpose: This study aimed to evaluate the treatment outcome after using diode laser disinfection of root canals in necrotic teeth with periapical radiolucency. Subjects and Methods: Thirty patients of age range between 20 and 50 years old were involved in this study. They were divided randomly into two groups (15 teeth each). Group I: Access cavity preparation was performed and microbiological sample (SI1) was taken. The root canal was prepared using ProTaper rotary instruments up to #F4 and irrigated with 2ml of 2.6% sodium hypochlorite, this was repeated after each instrument use with total volume 14ml. Smear layer removal with 17% EDTA (5ml) was performed, saline solution (5ml) was used as a final irrigant then, the canal was irradiated with 810 nm diode laser in a continuous wave mode with a power of 1.5 w then, microbiological sample (SI2) was taken. Group II: The same steps were followed as in group I up to the use of saline solution (5ml) as a final irrigant, then microbiological sample (SII2) was taken. The treatment outcome was evaluated clinically (pain recording using Visual Analogue Scale (VAS) at 6,12,24,48 and 72hours) and microbiologically (reduction in number of CFU of microorganisms). Results: There was no statistically significant difference between pain scores in the two groups. Group I showed statistically significant higher mean percentage reduction in bacterial and fungal counts than group II. Conclusion: 810 nm diode laser can be used as an adjunct to conventional root canal treatment in necrotic teeth with periapical radiolucency. Codex : 06/22.04 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2022.98162.1414 Restorative Dentistry (Removable Prosthodontics, Fixed Prosthodontics, Endodontics, Dental Biomaterials, Operative Dentistry)","PeriodicalId":7493,"journal":{"name":"Al-Azhar Dental Journal for Girls","volume":"83 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar Dental Journal for Girls","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/adjg.2022.98162.1414","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: This study aimed to evaluate the treatment outcome after using diode laser disinfection of root canals in necrotic teeth with periapical radiolucency. Subjects and Methods: Thirty patients of age range between 20 and 50 years old were involved in this study. They were divided randomly into two groups (15 teeth each). Group I: Access cavity preparation was performed and microbiological sample (SI1) was taken. The root canal was prepared using ProTaper rotary instruments up to #F4 and irrigated with 2ml of 2.6% sodium hypochlorite, this was repeated after each instrument use with total volume 14ml. Smear layer removal with 17% EDTA (5ml) was performed, saline solution (5ml) was used as a final irrigant then, the canal was irradiated with 810 nm diode laser in a continuous wave mode with a power of 1.5 w then, microbiological sample (SI2) was taken. Group II: The same steps were followed as in group I up to the use of saline solution (5ml) as a final irrigant, then microbiological sample (SII2) was taken. The treatment outcome was evaluated clinically (pain recording using Visual Analogue Scale (VAS) at 6,12,24,48 and 72hours) and microbiologically (reduction in number of CFU of microorganisms). Results: There was no statistically significant difference between pain scores in the two groups. Group I showed statistically significant higher mean percentage reduction in bacterial and fungal counts than group II. Conclusion: 810 nm diode laser can be used as an adjunct to conventional root canal treatment in necrotic teeth with periapical radiolucency. Codex : 06/22.04 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2022.98162.1414 Restorative Dentistry (Removable Prosthodontics, Fixed Prosthodontics, Endodontics, Dental Biomaterials, Operative Dentistry)
810nm二极管激光消毒单根牙髓坏死及根尖周放射率术后疼痛及微生物学评价:随机对照临床试验
目的:评价采用二极管激光消毒根尖周放射性坏死牙根管的治疗效果。对象和方法:30例年龄在20 ~ 50岁之间的患者参与了本研究。他们被随机分为两组(每组15颗牙齿)。第一组:预备通道腔,取微生物标本(SI1)。使用ProTaper旋转器械制备根管至#F4,用2ml 2.6%次氯酸钠冲洗,每次器械使用后重复,总容积14ml。用17% EDTA (5ml)去除涂片层,最后用生理盐水溶液(5ml)冲洗,用功率为1.5 w的810 nm二极管激光连续照射根管,取微生物样品(SI2)。第二组:与第一组相同的步骤,直到使用生理盐水溶液(5ml)作为最后的冲洗剂,然后取微生物样本(SII2)。对治疗结果进行临床评价(在6、12、24、48和72小时使用视觉模拟评分法(VAS)进行疼痛记录)和微生物学评价(微生物CFU数量减少)。结果:两组患者疼痛评分差异无统计学意义。1组细菌和真菌计数的平均减少百分比比2组有统计学意义。结论:810 nm二极管激光可作为常规根管治疗根尖周坏死牙的辅助治疗方法。法典:06/22.04 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2022.98162.1414修复牙科(可移动修复学,固定修复学,牙髓学,牙科生物材料,牙科手术)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信