{"title":"Electrical Discharges at Altitudes between 70,000 and 250,000 Feet","authors":"W. Dunbar","doi":"10.1109/TA.1965.4319807","DOIUrl":null,"url":null,"abstract":"Experimental measurements of electrical discharges caused by corona, glow discharges, and voltage breakdown were made under conditions encountered in aerospace vehicles operating within the 70,000 to 250,000 foot altitude range. All measurements were made in gases commonly used to pressurize spacecraft electrical and electronic compartments: nitrogen, nitrogenoxygen mixtures, and normal atmosphere at sea-level pressure. Test results show that: (1) the onset voltage at which the electrical discharge occurred is much lower for spaced wires than for bundled or twisted wires; (2) the onset voltage between wires increases as the insulation thickness and dielectric constant are increased and decreases as the wire diameter and wire spacing are increased; and (3) that the onset voltage of components depends on the type of component and its connection and installation.","PeriodicalId":13050,"journal":{"name":"IEEE Transactions on Aerospace","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1965-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Aerospace","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TA.1965.4319807","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Experimental measurements of electrical discharges caused by corona, glow discharges, and voltage breakdown were made under conditions encountered in aerospace vehicles operating within the 70,000 to 250,000 foot altitude range. All measurements were made in gases commonly used to pressurize spacecraft electrical and electronic compartments: nitrogen, nitrogenoxygen mixtures, and normal atmosphere at sea-level pressure. Test results show that: (1) the onset voltage at which the electrical discharge occurred is much lower for spaced wires than for bundled or twisted wires; (2) the onset voltage between wires increases as the insulation thickness and dielectric constant are increased and decreases as the wire diameter and wire spacing are increased; and (3) that the onset voltage of components depends on the type of component and its connection and installation.
在7万到25万英尺的高空放电
实验测量了由日冕、辉光放电和电压击穿引起的放电,这些放电是在7万至25万英尺高度范围内的航天飞行器中遇到的条件下进行的。所有的测量都是在通常用于给航天器电气和电子舱室加压的气体中进行的:氮、氮氧混合物和海平面压力下的正常大气。试验结果表明:(1)间隔线发生放电的起始电压远低于成束线和绞合线;(2)线间起始电压随绝缘厚度和介电常数的增大而增大,随线径和线距的增大而减小;(3)元件的起电压取决于元件的类型及其连接和安装。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信