X-ray microtomography of collagen and polylactide scaffolds in liquids.

M. Hannula, A. Haaparanta, Ilmari Tamminen, A. Aula, M. Kellomaki, J. Hyttinen
{"title":"X-ray microtomography of collagen and polylactide scaffolds in liquids.","authors":"M. Hannula, A. Haaparanta, Ilmari Tamminen, A. Aula, M. Kellomaki, J. Hyttinen","doi":"10.1109/EMBC.2015.7319668","DOIUrl":null,"url":null,"abstract":"Methods to image and assess the microstructure of polymer based biomaterials in liquid phase, for example cell culture medium, are well warranted. X-ray microtomography could provide a mean to visualize and analyze such structures. However, the density of such polymers is close to that of water and hence the X-ray contrast is poor. Moreover, if the biomaterials contain cells and are dried, the cell morphology may be distorted. In this paper we test phosphotungstic acid (PTA) staining to improve the contrast. We imaged collagen and PLA samples with μCT in air, water and alcohol. The methods were compared visually and with contrast to noise ratio calculated from the images. Our results demonstrate that with alcohol the PLA can be imaged also in liquid phase. PTA staining seems to be a good method to increase the contrast for collagen in μCT imaging.","PeriodicalId":72689,"journal":{"name":"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference","volume":"49 1","pages":"5626-9"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMBC.2015.7319668","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Methods to image and assess the microstructure of polymer based biomaterials in liquid phase, for example cell culture medium, are well warranted. X-ray microtomography could provide a mean to visualize and analyze such structures. However, the density of such polymers is close to that of water and hence the X-ray contrast is poor. Moreover, if the biomaterials contain cells and are dried, the cell morphology may be distorted. In this paper we test phosphotungstic acid (PTA) staining to improve the contrast. We imaged collagen and PLA samples with μCT in air, water and alcohol. The methods were compared visually and with contrast to noise ratio calculated from the images. Our results demonstrate that with alcohol the PLA can be imaged also in liquid phase. PTA staining seems to be a good method to increase the contrast for collagen in μCT imaging.
液体中胶原蛋白和聚乳酸支架的x射线显微断层扫描。
在液相中成像和评估聚合物基生物材料微观结构的方法,例如细胞培养基,是很有必要的。x射线显微断层扫描可以提供一种可视化和分析这些结构的方法。然而,这种聚合物的密度接近于水的密度,因此x射线对比很差。此外,如果生物材料含有细胞并将其干燥,则细胞形态可能会扭曲。本文对磷钨酸(PTA)染色进行了试验,以提高对比度。我们用μCT在空气、水和酒精中对胶原蛋白和聚乳酸进行成像。并与图像计算的噪声比进行了对比。我们的结果表明,在酒精的作用下,PLA也可以在液相中成像。在μCT成像中,PTA染色似乎是一种很好的增加胶原对比的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信