Medial Locking Plate Can Increase the Fixation Stability of Vertical Femoral Neck Fracture in Young Adults?

IF 0.2 Q4 ORTHOPEDICS
V. Zanardi, J. A. M. Guimarães, João Victor Silveira Möller, C. Roesler
{"title":"Medial Locking Plate Can Increase the Fixation Stability of Vertical Femoral Neck Fracture in Young Adults?","authors":"V. Zanardi, J. A. M. Guimarães, João Victor Silveira Möller, C. Roesler","doi":"10.1097/BTO.0000000000000623","DOIUrl":null,"url":null,"abstract":"Introduction: Vertical femoral neck fractures in young adults are usually caused by high-energy trauma. These injuries are difficult to stabilize due to significant shear forces acting on the fracture site. Their treatment is challenging and with high risks of complications, such as fixation failure, malunion, nonunion, and avascular necrosis of the femoral head. Material and Methods: It compared the biomechanical stability provided by 3 different fixation methods: (1) dynamic hip screw with derotation screw, (2) cannulated screws with a conventional medial bone plate, and (3) cannulated screws with a locked medial bone plate. These fixation structures were applied on fourth-generation medium-sized synthetic bones, with a 17 pound per cubic foot cellular foam core and cervico-diaphyseal angle of 120 degrees were used. The comparison was performed through biomechanical tests under cyclic loading followed by an ultimate load. The interfragmentary movement at the fracture site was the main variable for the cyclical phase. Results: The biomechanical comparison showed no statistical differences (P > 0.05) in stiffness, micromovement level, and mechanical resistance among the fixation techniques evaluated. Discussion: To stabilize the vertical femoral neck fracture in young patients, the use of a medial bone plate associated with cannulated screws on a “tie-rod” assembly is an option that supports the mechanical demand until the fracture healing. The locked medial plate did not provide an advantage compared with the conventional bone plate.","PeriodicalId":45336,"journal":{"name":"Techniques in Orthopaedics","volume":"4 1","pages":"126 - 130"},"PeriodicalIF":0.2000,"publicationDate":"2023-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BTO.0000000000000623","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Vertical femoral neck fractures in young adults are usually caused by high-energy trauma. These injuries are difficult to stabilize due to significant shear forces acting on the fracture site. Their treatment is challenging and with high risks of complications, such as fixation failure, malunion, nonunion, and avascular necrosis of the femoral head. Material and Methods: It compared the biomechanical stability provided by 3 different fixation methods: (1) dynamic hip screw with derotation screw, (2) cannulated screws with a conventional medial bone plate, and (3) cannulated screws with a locked medial bone plate. These fixation structures were applied on fourth-generation medium-sized synthetic bones, with a 17 pound per cubic foot cellular foam core and cervico-diaphyseal angle of 120 degrees were used. The comparison was performed through biomechanical tests under cyclic loading followed by an ultimate load. The interfragmentary movement at the fracture site was the main variable for the cyclical phase. Results: The biomechanical comparison showed no statistical differences (P > 0.05) in stiffness, micromovement level, and mechanical resistance among the fixation techniques evaluated. Discussion: To stabilize the vertical femoral neck fracture in young patients, the use of a medial bone plate associated with cannulated screws on a “tie-rod” assembly is an option that supports the mechanical demand until the fracture healing. The locked medial plate did not provide an advantage compared with the conventional bone plate.
内侧锁定钢板能提高青壮年股骨颈垂直骨折的固定稳定性?
年轻人股骨颈垂直骨折通常是由高能创伤引起的。由于作用在骨折部位的巨大剪切力,这些损伤很难稳定。其治疗具有挑战性,并发症风险高,如固定失败、不愈合、不愈合和股骨头缺血性坏死。材料和方法:比较了3种不同的固定方法提供的生物力学稳定性:(1)动力髋螺钉与旋转螺钉,(2)空心螺钉与常规内侧骨板,(3)空心螺钉与锁定内侧骨板。这些固定结构应用于第四代中型合成骨,采用每立方英尺17磅的细胞泡沫芯和120度的颈干夹角。通过循环载荷和极限载荷下的生物力学试验进行比较。断裂部位的碎块间运动是周期阶段的主要变量。结果:生物力学比较显示,不同固定方式在僵硬度、微动水平、机械阻力方面均无统计学差异(P > 0.05)。讨论:为了稳定年轻患者的垂直股骨颈骨折,在“拉杆”组件上使用内侧骨板和空心螺钉是一种支持机械需求的选择,直到骨折愈合。与传统的骨板相比,锁定的内侧钢板没有提供优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
31
期刊介绍: The purpose of Techniques in Orthopaedics is to provide information on the latest orthopaedic procedure as they are devised and used by top orthopaedic surgeons. The approach is technique-oriented, covering operations, manipulations, and instruments being developed and applied in such as arthroscopy, arthroplasty, and trauma. Each issue is guest-edited by an expert in the field and devoted to a single topic.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信