Control of Multilevel Inverter as Shunt Active Power Filter using Maximum Versoria Criterion

Praveen Bansal, Alka Singh
{"title":"Control of Multilevel Inverter as Shunt Active Power Filter using Maximum Versoria Criterion","authors":"Praveen Bansal, Alka Singh","doi":"10.1109/ICPECA47973.2019.8975392","DOIUrl":null,"url":null,"abstract":"This article discusses performance & control of based Shunt Active Power Filter (SAPF) as Multilevel Inverter (MLI)- using DSP of dSpace1104. MLI eliminates the use of bulky and high-cost transformers to connect APF. One of the best alternatives for improving power quality issues is the Cascaded H-bridge multilevel inverter (CHB-MLI) used as shunt active power filter (SAPF). A new controller has been designed based on Maximum Versoria Criterion algorithm for the control of SAPF. The presented control strategy estimates the load currents’ fundamental weight values. Grid reference current and magnitude are calculated using these weights and then the gating pulses for single phase CHB-MLI. The effective output of the presented SAPF control algorithm is illustrated by simulation results using Matlab / Simulink environment & test results are validated in the laboratory on the developed SAPF experimental prototype.","PeriodicalId":6761,"journal":{"name":"2019 International Conference on Power Electronics, Control and Automation (ICPECA)","volume":"5 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Power Electronics, Control and Automation (ICPECA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPECA47973.2019.8975392","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This article discusses performance & control of based Shunt Active Power Filter (SAPF) as Multilevel Inverter (MLI)- using DSP of dSpace1104. MLI eliminates the use of bulky and high-cost transformers to connect APF. One of the best alternatives for improving power quality issues is the Cascaded H-bridge multilevel inverter (CHB-MLI) used as shunt active power filter (SAPF). A new controller has been designed based on Maximum Versoria Criterion algorithm for the control of SAPF. The presented control strategy estimates the load currents’ fundamental weight values. Grid reference current and magnitude are calculated using these weights and then the gating pulses for single phase CHB-MLI. The effective output of the presented SAPF control algorithm is illustrated by simulation results using Matlab / Simulink environment & test results are validated in the laboratory on the developed SAPF experimental prototype.
基于最大Versoria准则的并联有源电力滤波器多电平逆变器控制
本文讨论了基于并联型有源电力滤波器(SAPF)作为多电平逆变器(MLI)的性能与控制——基于dSpace1104的DSP。MLI消除了使用笨重和高成本的变压器来连接APF。改善电能质量问题的最佳替代方案之一是级联h桥多电平逆变器(CHB-MLI)作为并联有源电力滤波器(SAPF)。基于最大Versoria准则算法设计了一种新的SAPF控制控制器。提出的控制策略估计负载电流的基本权值。利用这些权重计算栅格参考电流和幅值,然后计算单相CHB-MLI的门控脉冲。在Matlab / Simulink环境下的仿真结果说明了所提出的SAPF控制算法的有效输出,并在实验室对所研制的SAPF实验样机进行了测试验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信