{"title":"Extraction of B12 Reference Intervals from a Large Amount of General Patient Data","authors":"D. Gavars, D. Perminov, Ē. Tauckels, I. Lindenberga, A. Tutāne, A. Auce","doi":"10.2478/prolas-2022-0050","DOIUrl":null,"url":null,"abstract":"Abstract This study compared the reference intervals (RI) of B12 vitamin concentration in blood found in the literature with RIs extracted from data accumulated from a large number of patients by E. Gulbis Laboratory in Latvia. This paper investigated and demonstrated the possibility of using large amounts of random patient data to establish the RI for clinical laboratory tests. The blood level of B12 vitamin was selected as the model system for this study. The study used blind data for B12 blood level measurements from 132 379 patients accumulated in E. Gulbis Laboratory over a period of 15 years. In order to establish the reference intervals, the frequency distribution of log transformed B12 values was fit to a Gaussian distribution. The established B12 reference interval of 196 pg/ml and 942 pg/ml was found to be in good agreement with RIs reported elsewhere.","PeriodicalId":20651,"journal":{"name":"Proceedings of the Latvian Academy of Sciences. Section B. Natural, Exact, and Applied Sciences.","volume":"26 1","pages":"333 - 337"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Latvian Academy of Sciences. Section B. Natural, Exact, and Applied Sciences.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/prolas-2022-0050","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Multidisciplinary","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract This study compared the reference intervals (RI) of B12 vitamin concentration in blood found in the literature with RIs extracted from data accumulated from a large number of patients by E. Gulbis Laboratory in Latvia. This paper investigated and demonstrated the possibility of using large amounts of random patient data to establish the RI for clinical laboratory tests. The blood level of B12 vitamin was selected as the model system for this study. The study used blind data for B12 blood level measurements from 132 379 patients accumulated in E. Gulbis Laboratory over a period of 15 years. In order to establish the reference intervals, the frequency distribution of log transformed B12 values was fit to a Gaussian distribution. The established B12 reference interval of 196 pg/ml and 942 pg/ml was found to be in good agreement with RIs reported elsewhere.
从大量普通患者数据中提取B12参考区间
本研究将文献中发现的血液中B12维生素浓度的参考区间(RI)与拉脱维亚E. Gulbis实验室从大量患者数据中提取的RIs进行了比较。本文调查并证明了使用大量随机患者数据来建立临床实验室检测的RI的可能性。本研究选择血中维生素B12水平作为模型系统。该研究使用了E. Gulbis实验室15年来收集的132 379名患者的B12血水平的盲法数据。为了建立参考区间,将对数变换后的B12值的频率分布拟合为高斯分布。建立的B12参考区间为196 pg/ml和942 pg/ml,与其他文献报道的RIs一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.70
自引率
0.00%
发文量
61
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信