{"title":"Facility for calibration of photometers for measurement of temporal light modulation","authors":"PR Dekker, A.L. van Bloois","doi":"10.1177/14771535231159289","DOIUrl":null,"url":null,"abstract":"A facility for calibration of temporal light modulation (TLM) photometers has been developed. The facility is based on a laser-fed reference integrating sphere source, the optical input power of which can be modulated with an acousto-optic modulator. A system of photodiodes, amplifiers and an analogue-to-digital converter is used to sample the temporally modulated irradiance at one of the exit ports of the source. With the facility, a TLM photometer was calibrated for display contrast ratio root mean square with an absolute combined standard uncertainty of 0.037%. In addition, the facility has been characterised with the aim of measuring flicker and stroboscopic effect, considering the Ecodesign ‘Single Lighting Regulation’. The frequency response of the facility is shown to be sufficient to accommodate measurements of flicker and the stroboscopic effect.","PeriodicalId":18133,"journal":{"name":"Lighting Research & Technology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2023-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lighting Research & Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/14771535231159289","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

A facility for calibration of temporal light modulation (TLM) photometers has been developed. The facility is based on a laser-fed reference integrating sphere source, the optical input power of which can be modulated with an acousto-optic modulator. A system of photodiodes, amplifiers and an analogue-to-digital converter is used to sample the temporally modulated irradiance at one of the exit ports of the source. With the facility, a TLM photometer was calibrated for display contrast ratio root mean square with an absolute combined standard uncertainty of 0.037%. In addition, the facility has been characterised with the aim of measuring flicker and stroboscopic effect, considering the Ecodesign ‘Single Lighting Regulation’. The frequency response of the facility is shown to be sufficient to accommodate measurements of flicker and the stroboscopic effect.
校正用于测量时间光调制的光度计的设备
研制了一种时间光调制(TLM)光度计定标装置。该装置基于激光馈入参考积分球源,其光输入功率可通过声光调制器进行调制。一个由光电二极管、放大器和模数转换器组成的系统用于在光源的一个出口端口采样暂时调制的辐照度。利用该设备,对TLM光度计进行了显示对比度均方根校准,绝对组合标准不确定度为0.037%。此外,考虑到Ecodesign的“单一照明法规”,该设施的特点是测量闪烁和频闪效应。该设备的频率响应显示足以适应闪烁和频闪效应的测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Lighting Research & Technology
Lighting Research & Technology 工程技术-光学
CiteScore
5.40
自引率
16.00%
发文量
69
审稿时长
>12 weeks
期刊介绍: Lighting Research & Technology (LR&T) publishes original peer-reviewed research on all aspects of light and lighting and is published in association with The Society of Light and Lighting. LR&T covers the human response to light, the science of light generation, light control and measurement plus lighting design for both interior and exterior environments, as well as daylighting, energy efficiency and sustainability
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信