Study of glaring effect from light emitting diodes via lens approach

IF 0.3 4区 材料科学 Q4 MATERIALS SCIENCE, MULTIDISCIPLINARY
K. Jocelynn, W. Lim
{"title":"Study of glaring effect from light emitting diodes via lens approach","authors":"K. Jocelynn, W. Lim","doi":"10.1504/ijnt.2022.124496","DOIUrl":null,"url":null,"abstract":"- The purpose of this study was to evaluate the glaring effect from light emitting diode (LED) streetlights using two different brands of lenses. The evaluation was performed by using DIALux 4.1.3 with 70 W LED luminaires by taking into consideration of the same road lighting designs at a pole distance of 35 m and pole height of 10 m on a 7 m wide road. Calculation was performed on a section defined by one pole on one side of the road (single row). The pole height, light overhang and boom length was 10 m, 1 m and 1.5 m, respectively. The light loss factor was 0.85. Tracepro was used to simulate the distribution of light by tracing rays. All mounted luminaries have three zones of light outputs, which were the Backlight, Uplight and Frontlight (Glare) known as BUG rating. The lower the BUG rating was, the fewer light trespass problems the fixture would cause.","PeriodicalId":14128,"journal":{"name":"International Journal of Nanotechnology","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Nanotechnology","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1504/ijnt.2022.124496","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

- The purpose of this study was to evaluate the glaring effect from light emitting diode (LED) streetlights using two different brands of lenses. The evaluation was performed by using DIALux 4.1.3 with 70 W LED luminaires by taking into consideration of the same road lighting designs at a pole distance of 35 m and pole height of 10 m on a 7 m wide road. Calculation was performed on a section defined by one pole on one side of the road (single row). The pole height, light overhang and boom length was 10 m, 1 m and 1.5 m, respectively. The light loss factor was 0.85. Tracepro was used to simulate the distribution of light by tracing rays. All mounted luminaries have three zones of light outputs, which were the Backlight, Uplight and Frontlight (Glare) known as BUG rating. The lower the BUG rating was, the fewer light trespass problems the fixture would cause.
用透镜法研究发光二极管的眩光效应
-本研究的目的是评估使用两种不同品牌透镜的发光二极管(LED)路灯的眩光效果。采用DIALux 4.1.3进行评估,采用70 W LED灯具,在7 m宽的道路上,考虑相同的道路照明设计,杆距为35 m,杆高为10 m。计算在道路一侧(单排)的一根杆子定义的路段上进行。杆高10 m,轻悬垂1 m,臂长1.5 m。光损失因子为0.85。Tracepro通过追踪光线来模拟光的分布。所有安装的灯具都有三个区域的光输出,即背光源,上行光源和前光源(眩光),称为BUG评级。BUG等级越低,灯具引起的光侵入问题就越少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Nanotechnology
International Journal of Nanotechnology 工程技术-材料科学:综合
CiteScore
0.60
自引率
20.00%
发文量
45
审稿时长
6-12 weeks
期刊介绍: IJNT offers a multidisciplinary source of information in all subjects and topics related to Nanotechnology, with fundamental, technological, as well as societal and educational perspectives. Special issues are regularly devoted to research and development of nanotechnology in individual countries and on specific topics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信