{"title":"A PARAMETRIC STUDY OF CODE-BASED PERFORMANCE LIMITS FOR WIDE BEAMS","authors":"E. Tore, Talip Demiral","doi":"10.13167/2014.8.1","DOIUrl":null,"url":null,"abstract":"In this study, we compared the performance limits of building codes and assessed whether these limits could be applied to wide beams. We performed a parametric study, investigating the longitudinal reinforcement ratio, beam width, steel class, and type and spacing of the transverse reinforcement. We obtained the following results from these analyses: Increasing the longitudinal reinforcement ratio reduced the deformation limit corresponding to code-based performance limits. Changing the confinement properties significantly affected the TEC 2007 and ASCE/SEI 41 limits. The performance limits defined by EC8 and ASCE/SEI 41 had similar corresponding plastic deformations, lower than those corresponding to the TEC 2007 strain-based damage limits. The results show that assessing the performance of wide beams by using the performance limits from different codes could produce contradictory results.","PeriodicalId":53887,"journal":{"name":"Electronic Journal of the Faculty of Civil Engineering Osijek-e-GFOS","volume":"5 1","pages":"1-11"},"PeriodicalIF":0.6000,"publicationDate":"2014-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electronic Journal of the Faculty of Civil Engineering Osijek-e-GFOS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13167/2014.8.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 1
Abstract
In this study, we compared the performance limits of building codes and assessed whether these limits could be applied to wide beams. We performed a parametric study, investigating the longitudinal reinforcement ratio, beam width, steel class, and type and spacing of the transverse reinforcement. We obtained the following results from these analyses: Increasing the longitudinal reinforcement ratio reduced the deformation limit corresponding to code-based performance limits. Changing the confinement properties significantly affected the TEC 2007 and ASCE/SEI 41 limits. The performance limits defined by EC8 and ASCE/SEI 41 had similar corresponding plastic deformations, lower than those corresponding to the TEC 2007 strain-based damage limits. The results show that assessing the performance of wide beams by using the performance limits from different codes could produce contradictory results.