{"title":"Thermal response of a ferrocement cavity wall under direct fire","authors":"W. Al-Rifaie, Khaled Al-Enezi, W. Ahmed","doi":"10.1080/2093761X.2015.1116416","DOIUrl":null,"url":null,"abstract":"AbstractOne of the main challenges for building designs is to provide comfort to its occupants at a low cost. The present investigation aims to study the performance of a ferrocement cavity wall under heating by means of applying direct fire to two ferrocement leaves with a space in between to be filled with insulation material. The main parameters considered in the present investigation are the fire temperature at its core and the space between the two ferrocement leaves. All leaves were subjected to direct fire for 2 hours. The performance of the ferrocement cavity wall was observed by reading an infrared thermometer instrument and examining the crack patterns on the wall panel. It is concluded that increasing the cavity wall space affected the degree of insulation, while the degree of insulation is not affected by the type of insulation material. It is also concluded that hair cracks appeared on the surface of the ferrocement leave facing the fire when the temperature reached 1300°C with the core of th...","PeriodicalId":38108,"journal":{"name":"International Journal of Sustainable Building Technology and Urban Development","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/2093761X.2015.1116416","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Sustainable Building Technology and Urban Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/2093761X.2015.1116416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 3
Abstract
AbstractOne of the main challenges for building designs is to provide comfort to its occupants at a low cost. The present investigation aims to study the performance of a ferrocement cavity wall under heating by means of applying direct fire to two ferrocement leaves with a space in between to be filled with insulation material. The main parameters considered in the present investigation are the fire temperature at its core and the space between the two ferrocement leaves. All leaves were subjected to direct fire for 2 hours. The performance of the ferrocement cavity wall was observed by reading an infrared thermometer instrument and examining the crack patterns on the wall panel. It is concluded that increasing the cavity wall space affected the degree of insulation, while the degree of insulation is not affected by the type of insulation material. It is also concluded that hair cracks appeared on the surface of the ferrocement leave facing the fire when the temperature reached 1300°C with the core of th...
期刊介绍:
The International Journal of Sustainable Building Technology and Urban Development is the official publication of the Sustainable Building Research Center and serves as a resource to professionals and academics within the architecture and sustainability community. The International Journal of Sustainable Building Technology and Urban Development aims to support its academic community by disseminating studies on sustainable building technology, focusing on issues related to sustainable approaches in the construction industry to reduce waste and mass consumption, integration of advanced architectural technologies and environmentalism, sustainable building maintenance, life cycle cost (LCC), social issues, education and public policies relating to urban development and architecture .