Identifying the Origin of Anomalous High Tropospheric Ozone in the Ozonesonde Data at Uccle by Comparison with Nearby De Bilt

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
R. van Malderen, H. De Backer, A. Delcloo, M. Allaart
{"title":"Identifying the Origin of Anomalous High Tropospheric Ozone in the Ozonesonde Data at Uccle by Comparison with Nearby De Bilt","authors":"R. van Malderen, H. De Backer, A. Delcloo, M. Allaart","doi":"10.1080/07055900.2014.886552","DOIUrl":null,"url":null,"abstract":"Abstract The ozonesonde stations at Uccle (Belgium) and De Bilt (Netherlands), separated by only 175 km, offer a unique opportunity to test the influence of different ozonesonde types and different correction strategies, as well as to detect the presence of inhomogeneities in the ozonesonde time series resulting from changes in sounding equipment (solution, radiosonde, ozonesonde, interface, sounding software, etc.). In particular, we highlight a 2.5 year period (beginning of 2007 to mid-2009) of anomalous high tropospheric ozone values measured by ozonesondes at Uccle and compare these with the observations from De Bilt. Because the ozone deviations are only observed in the free troposphere where ozone concentrations are relatively low, and not in the boundary layer or the stratosphere, this issue is directly related to the sensitivity of ozonesondes. Therefore, the effect of every instrumental change, even though small, during this 2.5 year anomalous period is analyzed considering a change in the radiosounding equipment, different ozonesonde batches, operational differences at the stations, differences on ascent and descent during the anomalous period; an environmental cause is also examined. Unfortunately, one single, specific cause for the observed high tropospheric ozone values at Uccle could not be identified. There are two explanations consistent with the observations and not ruled out by the analysis here: 1) the majority of the ozonesondes used at Uccle between March 2007 and August 2009 needed longer conditioning of their sensors and, therefore, behaved more accurately at low ozone concentrations during their descent or when used a second time, and 2) an environmental origin arising from a local difference in the air mass between Uccle and De Bilt and between the ascent and descent.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/07055900.2014.886552","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1080/07055900.2014.886552","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 3

Abstract

Abstract The ozonesonde stations at Uccle (Belgium) and De Bilt (Netherlands), separated by only 175 km, offer a unique opportunity to test the influence of different ozonesonde types and different correction strategies, as well as to detect the presence of inhomogeneities in the ozonesonde time series resulting from changes in sounding equipment (solution, radiosonde, ozonesonde, interface, sounding software, etc.). In particular, we highlight a 2.5 year period (beginning of 2007 to mid-2009) of anomalous high tropospheric ozone values measured by ozonesondes at Uccle and compare these with the observations from De Bilt. Because the ozone deviations are only observed in the free troposphere where ozone concentrations are relatively low, and not in the boundary layer or the stratosphere, this issue is directly related to the sensitivity of ozonesondes. Therefore, the effect of every instrumental change, even though small, during this 2.5 year anomalous period is analyzed considering a change in the radiosounding equipment, different ozonesonde batches, operational differences at the stations, differences on ascent and descent during the anomalous period; an environmental cause is also examined. Unfortunately, one single, specific cause for the observed high tropospheric ozone values at Uccle could not be identified. There are two explanations consistent with the observations and not ruled out by the analysis here: 1) the majority of the ozonesondes used at Uccle between March 2007 and August 2009 needed longer conditioning of their sensors and, therefore, behaved more accurately at low ozone concentrations during their descent or when used a second time, and 2) an environmental origin arising from a local difference in the air mass between Uccle and De Bilt and between the ascent and descent.
通过与附近De Bilt的比较,在Uccle臭氧探测资料中识别对流层高层异常臭氧的来源
比利时Uccle和荷兰De Bilt的臭氧探空站相距仅175公里,提供了一个独特的机会来测试不同臭氧探空类型和不同校正策略的影响,以及检测由于探测设备(溶液、无线电探空仪、臭氧探空仪、接口、探测软件等)变化而导致的臭氧探空时间序列不均匀性的存在。特别地,我们强调了2.5年期间(2007年初至2009年年中)由Uccle的臭氧仪测量到的对流层臭氧异常高值,并将其与De Bilt的观测结果进行了比较。由于臭氧偏差只在臭氧浓度相对较低的自由对流层中观测到,而在边界层或平流层中没有观测到,因此这一问题与臭氧探测器的灵敏度直接相关。因此,在这2.5年的异常期间,考虑到无线电探测设备的变化、不同的臭氧探空批次、台站的操作差异、异常期间上升和下降的差异,分析了每一次仪器变化的影响,即使很小;环境因素也被研究。不幸的是,无法确定在ucle观测到的高对流层臭氧值的一个单一的具体原因。有两种解释与观测一致,不排除分析:1)大部分臭氧探测仪使用Uccle 2007年3月和2009年8月之间需要长调节传感器和,因此,表现得更准确地在低臭氧浓度下降或第二次使用时,和2)环境产生的起源从当地空气质量差Uccle和德印度之间之间的上升和下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信