M. Omidiora, N. Elkalashy, M. Lehtonen, M. Abdel-Rahman
{"title":"Modelling and evaluation of the lightning arc between a power line and a nearby tree","authors":"M. Omidiora, N. Elkalashy, M. Lehtonen, M. Abdel-Rahman","doi":"10.1002/ETEP.606","DOIUrl":null,"url":null,"abstract":"SUMMARY \n \nThis paper addresses the modification of the existing dynamic arc model for lightning arc simulation application. The modified dynamic arc model combines the static and the dynamic arc equations that are already established in the literature to reproduce an arc fault involving a lightning-struck tree and a nearby power distribution line during rainfall. The results of experimental studies regarding arc creation between a tree and a nearby power line with artificial rainfall were obtained. A complete model of this phenomenon is reproduced using the electromagnetic transient program (ATP/EMTP) and the existing static and dynamic arc equations. The essential reason for modifying this model is graphically shown with a comparison of the dynamic arc and the modified dynamic arc models. The performance of the arc phenomenon was examined using a typical Finnish distribution network design. By means of simulation using the modified dynamic arc, developed within the ATP/EMTP software with its Transient Analysis Control System features, the lightning arc performance of the MV/LV network under the influence of nearby trees and the network characteristics is analyzed. It is expected that such a model can be included in the existing ATP/EMTP software packages for simulating power system transients. Copyright © 2011 John Wiley & Sons, Ltd.","PeriodicalId":50474,"journal":{"name":"European Transactions on Electrical Power","volume":"22 1","pages":"787-811"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/ETEP.606","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Transactions on Electrical Power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ETEP.606","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
电力线与附近树木间闪电弧的模拟与评估
针对雷电电弧仿真应用,对现有动态电弧模型进行了修正。修正的动态电弧模型结合了文献中已建立的静态电弧方程和动态电弧方程,再现了降雨过程中雷击树木与附近配电线路的电弧故障。给出了人工降雨条件下树木与附近输电线之间产生电弧的实验研究结果。利用电磁瞬变程序(ATP/EMTP)和现有的静态和动态电弧方程再现了这一现象的完整模型。通过动态电弧模型与修正后的动态电弧模型的比较,以图形化的方式说明了修改该模型的根本原因。采用典型的芬兰配电网设计考察了电弧现象的性能。利用具有暂态分析控制系统功能的ATP/EMTP软件开发的改进动态电弧进行仿真,分析了邻近树木影响下中低压电网的雷电电弧性能和网络特性。期望该模型能够包含在现有的用于电力系统暂态仿真的ATP/EMTP软件包中。版权所有©2011 John Wiley & Sons, Ltd
本文章由计算机程序翻译,如有差异,请以英文原文为准。