A validated reverse-phase high performance liquid chromatography (RP-HPLC) method for the quantification of Gamma- tocotrienol in tocotrienol rich fractions of crude palm oil
{"title":"A validated reverse-phase high performance liquid chromatography (RP-HPLC) method for the quantification of Gamma- tocotrienol in tocotrienol rich fractions of crude palm oil","authors":"R. S. Nair, N. Billa, A. Morris","doi":"10.2174/1573401317666210803155717","DOIUrl":null,"url":null,"abstract":"\n\nPalm oil and its constituents have wide applications in food, cosmetics and pharmaceutical industries. The tocotrienol-rich fractions of crude palm oil have drawn greater research interest in recent years due to its potent health benefits. Therefore, reliable and validated analytical methods are essential for the quantification of tocotrienols. \n\n\n\nThis study aimed to develop a simple and economical RP-HPLC method for the quantification of gamma-tocotrienol in tocotrienol rich fractions of crude palm oil.\n\n\n\nAn Agilent HPLC system supplied with a Diode Array detector and an auto-injector system was used for the method development, and the wavelength was set 295 nm. A reversed-phase C18 column maintained at 30 °C using a mobile phase composition of methanol: water (95:05) at a flow rate of 1 mL/min was used for the analysis. The developed method was validated according to ICH guidelines. \n\n\n\nA symmetrical peak of gamma-tocotrienol was observed at 8.7 minutes with minimal peak tailing (between 0.76 and 0.78), and an acceptable resolution above 2.0. Excellent linearity was evident with R2 values 0.9996 and 0.9991 for intra-day and inter-day respectively. The method demonstrated a high precision (%RSD values ≤ 5.8%) and accuracy (%RE<9.6%). The LOD and LOQ of gamma-tocotrienol were determined as 1.4 μg/mL and 4.2 μg/mL respectively. The system suitability studies indicate that the chromatographic parameters are well within the acceptable limit.\n\n\n\nIn conclusion, the developed RP-HPLC method is rapid, precise, stable and economical for the quantification of gamma-tocotrienol.\n","PeriodicalId":10944,"journal":{"name":"Current Nutrition & Food Science","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Nutrition & Food Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1573401317666210803155717","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUTRITION & DIETETICS","Score":null,"Total":0}
引用次数: 1
Abstract
Palm oil and its constituents have wide applications in food, cosmetics and pharmaceutical industries. The tocotrienol-rich fractions of crude palm oil have drawn greater research interest in recent years due to its potent health benefits. Therefore, reliable and validated analytical methods are essential for the quantification of tocotrienols.
This study aimed to develop a simple and economical RP-HPLC method for the quantification of gamma-tocotrienol in tocotrienol rich fractions of crude palm oil.
An Agilent HPLC system supplied with a Diode Array detector and an auto-injector system was used for the method development, and the wavelength was set 295 nm. A reversed-phase C18 column maintained at 30 °C using a mobile phase composition of methanol: water (95:05) at a flow rate of 1 mL/min was used for the analysis. The developed method was validated according to ICH guidelines.
A symmetrical peak of gamma-tocotrienol was observed at 8.7 minutes with minimal peak tailing (between 0.76 and 0.78), and an acceptable resolution above 2.0. Excellent linearity was evident with R2 values 0.9996 and 0.9991 for intra-day and inter-day respectively. The method demonstrated a high precision (%RSD values ≤ 5.8%) and accuracy (%RE<9.6%). The LOD and LOQ of gamma-tocotrienol were determined as 1.4 μg/mL and 4.2 μg/mL respectively. The system suitability studies indicate that the chromatographic parameters are well within the acceptable limit.
In conclusion, the developed RP-HPLC method is rapid, precise, stable and economical for the quantification of gamma-tocotrienol.
期刊介绍:
Current Nutrition & Food Science publishes frontier reviews on all the latest advances on basic and clinical nutrition and food sciences. The journal aims to publish the highest quality review articles dedicated to research in the field. The journal is essential reading for all nutrition and food scientists.