Restoration corrosion survey of the steel structure of peron hall of the Main railway station in Prague

Q3 Materials Science
P. Pokorný, M. Hrabánek, H. Geiplová
{"title":"Restoration corrosion survey of the steel structure of peron hall of the Main railway station in Prague","authors":"P. Pokorný, M. Hrabánek, H. Geiplová","doi":"10.2478/kom-2019-0001","DOIUrl":null,"url":null,"abstract":"Abstract This article presents the results of the corrosion survey of the load-bearing structure of the main hall of the Main railway station in Prague. The chemical composition and microscopy view of the metal alloy has been explored, the current state of the anti-corrosion protection system as well as its composition were also evaluated. The corrosion damage of sheets and reinforcements of individual columns of the peron hall is also reported. The corrosion damage of the plates and reinforcements is locally very significant and is related to the drainage of rain water from the damaged roof structure. Renovation is also necessary for the protective coating system. The article concludes a restoration project that fully respects the historical form of the construction of the early twentieth century with minimal compromise.","PeriodicalId":17911,"journal":{"name":"Koroze a ochrana materialu","volume":"63 1","pages":"1 - 10"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Koroze a ochrana materialu","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/kom-2019-0001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Materials Science","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract This article presents the results of the corrosion survey of the load-bearing structure of the main hall of the Main railway station in Prague. The chemical composition and microscopy view of the metal alloy has been explored, the current state of the anti-corrosion protection system as well as its composition were also evaluated. The corrosion damage of sheets and reinforcements of individual columns of the peron hall is also reported. The corrosion damage of the plates and reinforcements is locally very significant and is related to the drainage of rain water from the damaged roof structure. Renovation is also necessary for the protective coating system. The article concludes a restoration project that fully respects the historical form of the construction of the early twentieth century with minimal compromise.
布拉格火车总站佩隆大厅钢结构修复腐蚀调查
本文介绍了对布拉格火车总站大厅承重结构腐蚀情况的调查结果。对金属合金的化学成分和微观形貌进行了探讨,并对防腐保护体系的现状及其组成进行了评价。文中还报道了佩隆大厅单柱板和钢筋的腐蚀破坏情况。板和钢筋的腐蚀损伤局部非常严重,与受损屋顶结构的雨水排放有关。保护涂层系统也需要进行翻新。文章总结了一个修复项目,该项目充分尊重20世纪初建筑的历史形式,并尽量减少妥协。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Koroze a ochrana materialu
Koroze a ochrana materialu Materials Science-Materials Science (all)
CiteScore
3.00
自引率
0.00%
发文量
8
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信