Minle Chen, Jia Xu, Feifei Chen, Quan Zhou, Shuanghu Wang, Aixia Han
{"title":"Validated UPLC-MS/MS method for the determination of ivosidenib in rat plasma: Application to a pharmacokinetic study","authors":"Minle Chen, Jia Xu, Feifei Chen, Quan Zhou, Shuanghu Wang, Aixia Han","doi":"10.1556/1326.2022.01053","DOIUrl":null,"url":null,"abstract":"\n Ivosidenib (AG-120) is an unlisted, but estimated to be valid, oral inhibitor for isocitrate dehydrogenase 1 (IDH1) in the phase Ⅰ study of IDH1-mutated acute myeloid leukemia (AML) patients. This paper presents the investigation and validation of a rapid, effective, qualitative and quantitative determination method of ivosidenib in rat plasma by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). The samples were treated using acetonitrile precipitation to remove protein influence. Then, the supernatant was extracted to analyze plasma concentration traits. In the UPLC system, acetonitrile and water containing 0.1% formic acid were selected as a cosolvent mobile phase, applying a gradient elution to isolate compounds in a C18 column. Mass detections were performed on a triple quadruple mass spectrometer in positive ion mode. Electroshock characteristic fragment ionization was used for m/z 583.95→214.53 for ivosidenib for quantitative determination, m/z 583.95→186.6 for qualitative determination, and m/z 492.06→354.55 for IS. The selectivity, linearity, stability, accuracy and precision were verified by reaching the guideline criteria from European Medicine Agency (EMA) and the Food and Drug Administration (FDA). The calibration curve was linear over the concentration range of 2–2,000 ng mL−1 for ivosidenib in rat plasma with a lower limit of quantification (LLOQ) of at least 2 ng mL−1. Additionally, there was no distinct matrix effect or carry-over phenomenon. The method was successfully established and applied to separate ivosidenib from plasma, with the entire analytical process being performed within 3 min for each sample, which shows high-efficiency and convenience for further studies of ivosidenib.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2022-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2022.01053","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Ivosidenib (AG-120) is an unlisted, but estimated to be valid, oral inhibitor for isocitrate dehydrogenase 1 (IDH1) in the phase Ⅰ study of IDH1-mutated acute myeloid leukemia (AML) patients. This paper presents the investigation and validation of a rapid, effective, qualitative and quantitative determination method of ivosidenib in rat plasma by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). The samples were treated using acetonitrile precipitation to remove protein influence. Then, the supernatant was extracted to analyze plasma concentration traits. In the UPLC system, acetonitrile and water containing 0.1% formic acid were selected as a cosolvent mobile phase, applying a gradient elution to isolate compounds in a C18 column. Mass detections were performed on a triple quadruple mass spectrometer in positive ion mode. Electroshock characteristic fragment ionization was used for m/z 583.95→214.53 for ivosidenib for quantitative determination, m/z 583.95→186.6 for qualitative determination, and m/z 492.06→354.55 for IS. The selectivity, linearity, stability, accuracy and precision were verified by reaching the guideline criteria from European Medicine Agency (EMA) and the Food and Drug Administration (FDA). The calibration curve was linear over the concentration range of 2–2,000 ng mL−1 for ivosidenib in rat plasma with a lower limit of quantification (LLOQ) of at least 2 ng mL−1. Additionally, there was no distinct matrix effect or carry-over phenomenon. The method was successfully established and applied to separate ivosidenib from plasma, with the entire analytical process being performed within 3 min for each sample, which shows high-efficiency and convenience for further studies of ivosidenib.
期刊介绍:
Acta Chromatographica
Open Access
Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.