Perfusion Changes in Perforator-Based Propeller Flaps

Silvia Bernuth, A. Vater, Konrad F. Fuchs, R. Meffert, R. Jakubietz
{"title":"Perfusion Changes in Perforator-Based Propeller Flaps","authors":"Silvia Bernuth, A. Vater, Konrad F. Fuchs, R. Meffert, R. Jakubietz","doi":"10.1055/a-2086-4988","DOIUrl":null,"url":null,"abstract":"Abstract Background  To cover soft tissue defects, the perforator-based propeller flap offers the option to rotate healthy tissue into complex wounds. By rotating the flap, the perforator is torqued. As a result, perfusion changes are possible. Methods  A retrospective data analysis of patients was done, who received a propeller flap to cover soft tissue defects of the lower extremity as well as a peri- and postoperative perfusion monitoring with a laser-Doppler-spectrophotometry system. Additionally, patient-specific data were collected. Results  Seven patients were identified. Four patients experienced early complications, two epidermolysis of the distal flap areas, three wound healing disorders, and one partial flap necrosis. Intraoperative perfusion monitoring showed a decline of blood flow after incision of the flap, especially at distal flap site. In case of complications, there were prolonged blood flow declines up to the first postoperative day. Conclusion  Torqueing the perforator by rotating the flap can cause an impairment in inflow and outflow. If the impairment is prolonged, perfusion-associated complications are possible. The identification of a viable perforator is particularly important. In addition, a conservative postoperative mobilization is necessary to compensate for the impaired and adapting outflow.","PeriodicalId":34024,"journal":{"name":"Journal of Reconstructive Microsurgery Open","volume":"08 1","pages":"e45 - e50"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Reconstructive Microsurgery Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2086-4988","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background  To cover soft tissue defects, the perforator-based propeller flap offers the option to rotate healthy tissue into complex wounds. By rotating the flap, the perforator is torqued. As a result, perfusion changes are possible. Methods  A retrospective data analysis of patients was done, who received a propeller flap to cover soft tissue defects of the lower extremity as well as a peri- and postoperative perfusion monitoring with a laser-Doppler-spectrophotometry system. Additionally, patient-specific data were collected. Results  Seven patients were identified. Four patients experienced early complications, two epidermolysis of the distal flap areas, three wound healing disorders, and one partial flap necrosis. Intraoperative perfusion monitoring showed a decline of blood flow after incision of the flap, especially at distal flap site. In case of complications, there were prolonged blood flow declines up to the first postoperative day. Conclusion  Torqueing the perforator by rotating the flap can cause an impairment in inflow and outflow. If the impairment is prolonged, perfusion-associated complications are possible. The identification of a viable perforator is particularly important. In addition, a conservative postoperative mobilization is necessary to compensate for the impaired and adapting outflow.
基于穿孔器的螺旋桨襟翼灌注变化
摘要背景 为了覆盖软组织缺陷,基于穿孔的螺旋桨皮瓣提供了将健康组织旋转到复杂伤口的选择。通过旋转襟翼,穿孔器被扭转。因此,灌注变化是可能的。方法 对患者进行了回顾性数据分析,这些患者接受了螺旋桨皮瓣覆盖下肢软组织缺损,并使用激光多普勒分光光度法系统进行了围术期和术后灌注监测。此外,还收集了患者特定的数据。后果 确认了7名患者。4名患者出现早期并发症,2例远端皮瓣区域表皮松解,3例伤口愈合障碍,1例部分皮瓣坏死。术中灌注监测显示皮瓣切开后血流量下降,尤其是在皮瓣远端。在出现并发症的情况下,血流量持续下降,直至术后第一天。结论 通过旋转皮瓣扭转穿孔器可能会导致流入和流出受损。如果损伤时间延长,则可能出现灌注相关并发症。确定一个有活力的穿孔器是特别重要的。此外,保守的术后动员是必要的,以补偿受损和适应流出。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
6
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信