Climate Responsive Architecture in Warm Humid Climate - A Case of South Kanara Manor houses

Q2 Engineering
{"title":"Climate Responsive Architecture in Warm Humid Climate - A Case of South Kanara Manor houses","authors":"","doi":"10.30534/ijeter/2023/061162023","DOIUrl":null,"url":null,"abstract":"Thermal comfort is of utmost importance in an indoor environment. If people are living or working in unfavourable environments, the work efficiency is considerably affected. Hence it is the job of an Architect to design comfortable indoors. Warm humid climatic zones are prevalent within 15⁰ to 30⁰ north and south of equator. The main characteristic of this climatic zone is there is very little seasonal variation, humidity is more than 50% (RH) and precipitation is also very high. South Kanara is along the Konkan coast in the state of Karnataka, under the warm humid climatic zone. The main challenge in designing in warm humid climatic zone is the temperature and humidity are high throughout the year and people indoors are not comfortable most part of the year. Hence, they have to depend on active cooling systems. Vernacular structures which are specific to a climatic zone have come up after lot of experimentation with the use of locally available materials and techniques. Vernacular structures which are climate responsive architecture incorporate passive design strategies. Thermal comfort is achieved by appropriate orientation of the building, optimum size and orientation of the fenestration, adapt design of surrounding landscape feature, appropriate use of materials in construction of the building, enhanced wind movement in the interior by good planning, cutting down solar radiation entering into the interiors. This article explains in detail the passive strategies to be adopted in warm humid climatic zone Giving an insight into the climate responsive design strategies adopted in the vernacular structures of south Kanara manor houses.","PeriodicalId":13964,"journal":{"name":"International Journal of Emerging Trends in Engineering Research","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Emerging Trends in Engineering Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30534/ijeter/2023/061162023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Thermal comfort is of utmost importance in an indoor environment. If people are living or working in unfavourable environments, the work efficiency is considerably affected. Hence it is the job of an Architect to design comfortable indoors. Warm humid climatic zones are prevalent within 15⁰ to 30⁰ north and south of equator. The main characteristic of this climatic zone is there is very little seasonal variation, humidity is more than 50% (RH) and precipitation is also very high. South Kanara is along the Konkan coast in the state of Karnataka, under the warm humid climatic zone. The main challenge in designing in warm humid climatic zone is the temperature and humidity are high throughout the year and people indoors are not comfortable most part of the year. Hence, they have to depend on active cooling systems. Vernacular structures which are specific to a climatic zone have come up after lot of experimentation with the use of locally available materials and techniques. Vernacular structures which are climate responsive architecture incorporate passive design strategies. Thermal comfort is achieved by appropriate orientation of the building, optimum size and orientation of the fenestration, adapt design of surrounding landscape feature, appropriate use of materials in construction of the building, enhanced wind movement in the interior by good planning, cutting down solar radiation entering into the interiors. This article explains in detail the passive strategies to be adopted in warm humid climatic zone Giving an insight into the climate responsive design strategies adopted in the vernacular structures of south Kanara manor houses.
温湿气候下的气候响应型建筑——以南卡纳拉庄园住宅为例
在室内环境中,热舒适是最重要的。如果人们在不利的环境中生活或工作,工作效率就会受到很大影响。因此,设计舒适的室内环境是建筑师的工作。温暖潮湿的气候带在赤道以北和以南15⁰至30⁰范围内普遍存在。该气候带的主要特征是季节变化很小,湿度大于50% (RH),降水量也很高。南卡纳拉位于卡纳塔克邦的康坎海岸,属于温暖潮湿的气候带。暖湿气候区设计的主要挑战是一年四季温度和湿度都很高,室内大部分时间都不舒服。因此,他们必须依靠主动冷却系统。在使用当地可用的材料和技术进行了大量实验之后,出现了特定于气候带的乡土结构。乡土建筑是气候响应型建筑,采用被动式设计策略。热舒适是通过建筑的适当朝向、开窗的最佳尺寸和朝向、周围景观特征的适应性设计、建筑施工中材料的适当使用、通过良好的规划增强室内的风运动、减少进入室内的太阳辐射来实现的。本文详细解释了在温暖潮湿的气候带中采用的被动策略,从而深入了解卡纳拉南部庄园住宅乡土结构中采用的气候响应式设计策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
70
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信