Manipulation Rate Is Not Increased After Customized Total Knee Arthroplasty

A. Kay, W. Kurtz, Gregory Martin, B. Huber, R. Tait, T. Clyburn
{"title":"Manipulation Rate Is Not Increased After Customized Total Knee Arthroplasty","authors":"A. Kay, W. Kurtz, Gregory Martin, B. Huber, R. Tait, T. Clyburn","doi":"10.15438/RR.8.1.210","DOIUrl":null,"url":null,"abstract":"Introduction Manipulation under anesthesia (MUA) is a standard treatment for arthrofibrosis after total knee arthroplasty (TKA), with reported rates of 1.5-6%.  Customized TKA may have better outcomes by matching individual patient anatomy.  However, a previous study reported an unacceptably high rate of MUA for customized TKAs.  This study reports the incidence of MUA in a large cohort of second generation customized TKAs.  Methods:Data was collected prospectively on 360 2nd generation ConforMIS iTotal cruciate retaining TKAs.  MUA was performed for clinically significant arthrofibrosis.  Range of motion (ROM) and New Knee Society Scores (KSS) were evaluated at regular intervals for two years.   Results: 11/360 (3.05%) knees underwent MUA.  ROM overall improved from 115° to 125°, and from 112° to 122° in patients undergoing MUA.  KSS objective and functional scores in MUA patients increased from 57 to 98 and 41 to 90, respectively, and in the entire cohort increased from 65 to 96 and 45 to 86 at 2 years (p<0.05). No MUA patients underwent revision surgery.   Discussion and Conclusion:Customized TKA with second generation ConforMIS iTotal implants results in a MUA rate consistent with the literature for all designs. Additionally, patients exhibit significant increases in ROM and Knee Society Scores.  ","PeriodicalId":20884,"journal":{"name":"Reconstructive Review","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reconstructive Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15438/RR.8.1.210","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Introduction Manipulation under anesthesia (MUA) is a standard treatment for arthrofibrosis after total knee arthroplasty (TKA), with reported rates of 1.5-6%.  Customized TKA may have better outcomes by matching individual patient anatomy.  However, a previous study reported an unacceptably high rate of MUA for customized TKAs.  This study reports the incidence of MUA in a large cohort of second generation customized TKAs.  Methods:Data was collected prospectively on 360 2nd generation ConforMIS iTotal cruciate retaining TKAs.  MUA was performed for clinically significant arthrofibrosis.  Range of motion (ROM) and New Knee Society Scores (KSS) were evaluated at regular intervals for two years.   Results: 11/360 (3.05%) knees underwent MUA.  ROM overall improved from 115° to 125°, and from 112° to 122° in patients undergoing MUA.  KSS objective and functional scores in MUA patients increased from 57 to 98 and 41 to 90, respectively, and in the entire cohort increased from 65 to 96 and 45 to 86 at 2 years (p<0.05). No MUA patients underwent revision surgery.   Discussion and Conclusion:Customized TKA with second generation ConforMIS iTotal implants results in a MUA rate consistent with the literature for all designs. Additionally, patients exhibit significant increases in ROM and Knee Society Scores.  
定制全膝关节置换术后操作率未提高
引言麻醉下手法(MUA)是全膝关节置换术(TKA)后关节纤维化的标准治疗方法,据报道其发生率为1.5-6%。通过匹配个体患者的解剖结构,定制TKA可能会有更好的结果。然而,先前的一项研究报告称,定制TKA的MUA发生率高得令人无法接受。本研究报告了第二代定制TKA大队列中MUA的发生率。方法:前瞻性收集360例第二代ConforMIS i全交叉韧带保留TKA的数据。对具有临床意义的关节纤维化进行MUA。在两年内定期评估运动范围(ROM)和新膝关节学会评分(KSS)。结果:11/360(3.05%)膝关节行MUA。MUA患者的ROM总体从115°改善到125°,从112°改善到122°。2年时,MUA患者的KSS目标和功能评分分别从57分增加到98分和41分增加到90分,整个队列的KSS客观和功能评分从65分增加到96分和45分增加到86分(p<0.05)。没有MUA患者接受翻修手术。讨论和结论:使用第二代ConforMIS iTotal植入物定制TKA可使MUA率与所有设计的文献一致。此外,患者ROM和膝关节学会评分显著增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
2
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信