A standardised template for reporting lower limb kinematic waveform movement compensations from a sensor-based portable clinical movement analysis toolkit

K Button , M Felemban , JL Davies , K Nicholas , J Parry-Williams , Q Muaidi , M Al-Amri
{"title":"A standardised template for reporting lower limb kinematic waveform movement compensations from a sensor-based portable clinical movement analysis toolkit","authors":"K Button ,&nbsp;M Felemban ,&nbsp;JL Davies ,&nbsp;K Nicholas ,&nbsp;J Parry-Williams ,&nbsp;Q Muaidi ,&nbsp;M Al-Amri","doi":"10.1016/j.ipemt.2021.100001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>To develop a standardised template to support physiotherapist reporting of lower limb kinematic waveform data</p></div><div><h3>Design</h3><p>Within and between user agreement identification of movement compensation strategies.</p></div><div><h3>Setting</h3><p>University Health Board Physiotherapy Department</p></div><div><h3>Participants</h3><p>Fourteen individuals with anterior cruciate ligament reconstruction performed overground gait, double-leg squat, and stair ascent wearing body-worn sensors. Six users viewed 252 kinematic waveforms of hip, knee and ankle joint angles in the sagittal and frontal planes.</p></div><div><h3>Main outcome measures</h3><p>Between and within-user observed agreement and themes from movement analysis reports</p></div><div><h3>Results</h3><p>Between-user observed agreement for presence of a movement compensation was 0.6–0.9 for the sagittal plane and 0.75–1.0 for the frontal place. Within-user observed agreement was 0.57–1.00 for the sagittal plane and 0.71–1.00 for the frontal plane. Three themes and seven categories were identified from the waveform interpretations: Amount (qualitative and quantitative description), timing (phase, discrete time point, cycle), and nature (peak, range of motion, timing) of the compensation.</p></div><div><h3>Conclusion</h3><p>There was good agreement between users at identifying the presence of movement compensation from the kinematic waveforms, but there was variation in how movement compensations were described. An interactive report, a standardised template for interpretation of kinematic waveforms, and training to support the clinical application of a movement analysis toolkit are proposed.</p></div>","PeriodicalId":73507,"journal":{"name":"IPEM-translation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2667258821000017/pdfft?md5=f5cda8c9ff5164d4e90f1623a7d9c7bf&pid=1-s2.0-S2667258821000017-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IPEM-translation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667258821000017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives

To develop a standardised template to support physiotherapist reporting of lower limb kinematic waveform data

Design

Within and between user agreement identification of movement compensation strategies.

Setting

University Health Board Physiotherapy Department

Participants

Fourteen individuals with anterior cruciate ligament reconstruction performed overground gait, double-leg squat, and stair ascent wearing body-worn sensors. Six users viewed 252 kinematic waveforms of hip, knee and ankle joint angles in the sagittal and frontal planes.

Main outcome measures

Between and within-user observed agreement and themes from movement analysis reports

Results

Between-user observed agreement for presence of a movement compensation was 0.6–0.9 for the sagittal plane and 0.75–1.0 for the frontal place. Within-user observed agreement was 0.57–1.00 for the sagittal plane and 0.71–1.00 for the frontal plane. Three themes and seven categories were identified from the waveform interpretations: Amount (qualitative and quantitative description), timing (phase, discrete time point, cycle), and nature (peak, range of motion, timing) of the compensation.

Conclusion

There was good agreement between users at identifying the presence of movement compensation from the kinematic waveforms, but there was variation in how movement compensations were described. An interactive report, a standardised template for interpretation of kinematic waveforms, and training to support the clinical application of a movement analysis toolkit are proposed.

基于传感器的便携式临床运动分析工具包中用于报告下肢运动波形运动补偿的标准化模板
目的建立一个标准化的模板,以支持物理治疗师报告下肢运动波形数据,设计用户内部和用户之间的运动补偿策略识别。14名前交叉韧带重建患者穿戴穿戴式传感器,进行地上步态、双腿深蹲和爬楼梯。6名患者观察了252个髋关节、膝关节和踝关节矢状面和正面角度的运动学波形。结果:矢状面存在运动补偿的用户间观察一致性为0.6-0.9,额位存在运动补偿的用户间观察一致性为0.75-1.0。在用户内观察到的矢状面一致性为0.57-1.00,额面一致性为0.71-1.00。从波形解释中确定了三个主题和七个类别:补偿的数量(定性和定量描述),定时(相位,离散时间点,周期)和性质(峰值,运动范围,定时)。结论从运动学波形中识别运动补偿的存在,用户之间有很好的一致性,但在如何描述运动补偿方面存在差异。提出了一种交互式报告,一种用于解释运动波形的标准化模板,以及支持运动分析工具包临床应用的培训。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IPEM-translation
IPEM-translation Medicine and Dentistry (General)
自引率
0.00%
发文量
0
审稿时长
63 days
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信