{"title":"Compact Testing of Total Station Instruments Using Folded Optics","authors":"V. Pagounis, N. Merlemis, D. Anastasiou, O. Arabatzi, V. Zacharis, M. Tsakiri","doi":"10.2478/jaes-2022-0011","DOIUrl":null,"url":null,"abstract":"Abstract An optimized compact-based method is introduced that verifies the distance measuring precision of surveying instruments. The paper describes the improvement of the compact based method not only in establishing a compact facility by using shorter lengths and folded path but also in the assessment process by implementing the official ISO standard for electronic distance measuring equipment (ISO 17123-4). The method produces statistically comparable results to ISO standards and is suited for regular instrument checks in institutions with limited space available.","PeriodicalId":44808,"journal":{"name":"Journal of Applied Engineering Sciences","volume":"12 1","pages":"71 - 76"},"PeriodicalIF":1.0000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Engineering Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/jaes-2022-0011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract An optimized compact-based method is introduced that verifies the distance measuring precision of surveying instruments. The paper describes the improvement of the compact based method not only in establishing a compact facility by using shorter lengths and folded path but also in the assessment process by implementing the official ISO standard for electronic distance measuring equipment (ISO 17123-4). The method produces statistically comparable results to ISO standards and is suited for regular instrument checks in institutions with limited space available.
利用折叠光学对全站仪进行紧凑测试
摘要介绍了一种优化的基于紧凑型的测量仪器测距精度验证方法。本文介绍了基于紧凑型的方法的改进,不仅在通过使用较短的长度和折叠路径建立紧凑型设施方面,而且在通过实施电子测距设备的官方ISO标准(ISO 17123-4)的评估过程中。该方法产生了与ISO标准具有统计可比性的结果,适用于可用空间有限的机构的定期仪器检查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
9.10%
发文量
18
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信