Sun Jiangning, Pan Xiaodong, L. Xinfu, Wan Haojiang, Wei Guanghui
{"title":"Research on theoretical model of bulk current injection replacing radiation about shielded two-core wire","authors":"Sun Jiangning, Pan Xiaodong, L. Xinfu, Wan Haojiang, Wei Guanghui","doi":"10.11884/HPLPB202133.200354","DOIUrl":null,"url":null,"abstract":"Large-scale space simulation of high field intensity electromagnetic environment is difficult to test radiation effects, and there are gaps in the application of existing BCI (bulk current injection) technology to nonlinear system tests. The research on the equivalent alternative radiation test method of the shielded cable coupling channel is carried out. Taking the equal response of the tested equipment as the equivalent basis, an analysis model of the response of the EUT (equipment under test) under the two conditions of radiation method and injection method is established. The equivalent corresponding relationship between the injection excitation source voltage and the radiation field intensity is deduced, and the conditions and test methods for the equivalent replacement of radiation with BCI are proposed and verified by experiments. The research results show that the BCI method can be accurately equivalent to the radiation effect test of the EUT, and the test error does not exceed 2 dB, which can meet the actual needs of the project.","PeriodicalId":39871,"journal":{"name":"强激光与粒子束","volume":"33 1","pages":"073008-1-073008-11"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"强激光与粒子束","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.11884/HPLPB202133.200354","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
Large-scale space simulation of high field intensity electromagnetic environment is difficult to test radiation effects, and there are gaps in the application of existing BCI (bulk current injection) technology to nonlinear system tests. The research on the equivalent alternative radiation test method of the shielded cable coupling channel is carried out. Taking the equal response of the tested equipment as the equivalent basis, an analysis model of the response of the EUT (equipment under test) under the two conditions of radiation method and injection method is established. The equivalent corresponding relationship between the injection excitation source voltage and the radiation field intensity is deduced, and the conditions and test methods for the equivalent replacement of radiation with BCI are proposed and verified by experiments. The research results show that the BCI method can be accurately equivalent to the radiation effect test of the EUT, and the test error does not exceed 2 dB, which can meet the actual needs of the project.
高场强电磁环境的大尺度空间模拟难以测试辐射效应,现有的BCI (bulk current injection)技术在非线性系统测试中的应用存在空白。对屏蔽电缆耦合通道等效替代辐射测试方法进行了研究。以被测设备的等效响应为等效基础,建立了辐射法和注入法两种工况下EUT(被测设备)的响应分析模型。推导了注入激励源电压与辐射场强的等效对应关系,提出了用BCI等效替代辐射的条件和测试方法,并通过实验进行了验证。研究结果表明,BCI方法可以准确等效于EUT的辐射效应测试,测试误差不超过2 dB,可以满足工程的实际需要。