Carry P S Cheung, David S W Pun, Raymond Y F Tong, K. Hui
{"title":"First of its kind in Hong Kong - innovative reuse of treated effluent and enhanced \nenergy efficiency for air-conditioning systems","authors":"Carry P S Cheung, David S W Pun, Raymond Y F Tong, K. Hui","doi":"10.33430/v30n2thie-2022-0061","DOIUrl":null,"url":null,"abstract":"In Hong Kong, air-conditioning (A/C) systems are major consumers of electricity. Although water-cooled air-conditioning systems (WACSs) are more energy efficient, the need for water towers, water treatment and other operation and maintenance (O&M) demands restrain their application in most buildings. This paper reviews a pilot application of treated effluent from sewage treatment works as a cooling medium for the Direct Expansion type of A/C system within the treatment Plant. The Drainage Services Department (DSD) installed a WACS with a self-assembled effluent-cooled condenser to study the energy efficiency, cooling performance and actual O&M requirements of the new system over a one-year pilot. It revealed that an energy saving of up to 27.6% per year could be achieved when compared with a conventional air-cooled air-conditioning \nsystem (AACS). This innovative effluent cooling A/C system achieves innovative reuse of treated effluent as well as reduction in carbon footprint as a result of higher energy efficiency for sustainable development.","PeriodicalId":35587,"journal":{"name":"Transactions Hong Kong Institution of Engineers","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions Hong Kong Institution of Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33430/v30n2thie-2022-0061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
In Hong Kong, air-conditioning (A/C) systems are major consumers of electricity. Although water-cooled air-conditioning systems (WACSs) are more energy efficient, the need for water towers, water treatment and other operation and maintenance (O&M) demands restrain their application in most buildings. This paper reviews a pilot application of treated effluent from sewage treatment works as a cooling medium for the Direct Expansion type of A/C system within the treatment Plant. The Drainage Services Department (DSD) installed a WACS with a self-assembled effluent-cooled condenser to study the energy efficiency, cooling performance and actual O&M requirements of the new system over a one-year pilot. It revealed that an energy saving of up to 27.6% per year could be achieved when compared with a conventional air-cooled air-conditioning
system (AACS). This innovative effluent cooling A/C system achieves innovative reuse of treated effluent as well as reduction in carbon footprint as a result of higher energy efficiency for sustainable development.