D. Decurcio, J. A. Silvaa, Mateus Gehrke Barbosa, L. S. Chaves, M. Loureiro, C. Estrela
{"title":"Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatment","authors":"D. Decurcio, J. A. Silvaa, Mateus Gehrke Barbosa, L. S. Chaves, M. Loureiro, C. Estrela","doi":"10.15448/1980-6523.2017.4.30157","DOIUrl":null,"url":null,"abstract":"OBJECTIVE: To characterize the nucleus, cutting edge and to detect defects in surfaces of nickeltitanium (NiTi) instruments for endodontic retreatment.METHODS: The selected endodontic instruments (D-RaCe, ProTaper retreatment and Mtwo retreatment) were evaluated prior to their use in 30- and 50-fold magnification in scanning electron microscopy (SEM), for linear measurements of lateral cut edge areas and of the nucleus and the ratio between these measures. After use in simulated canals, faults in the active surface were analyzed by SEM with 30 and 50 times magnification, and 200 times magnification when faults were found. The images were examined by three evaluators, whose measurements were previously calibrated. The defects analyzed were crack, blunt and barb, and data were tabulated for analysis.RESULTS: The instruments studied differed in results. The D-RaCe system instruments had the highest nucleus:edge ratio, while ProTaper retreatment instruments yielded the lowest ratio. All instruments presented some defect, with the instruments Mtwo retreatment presenting two instruments with defects.CONCLUSION: All analyzed instruments presented some type of failure after using them for removal of the filling material of simulated root canals. The D-RaCe system presented the highest edge measurements and the smallest nucleus measurements, contrary to the ProTaper retreatment system, which presented the smallest edge measurements and the largest core measurements.","PeriodicalId":38878,"journal":{"name":"Revista Odonto Ciencia","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.15448/1980-6523.2017.4.30157","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Odonto Ciencia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15448/1980-6523.2017.4.30157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
OBJECTIVE: To characterize the nucleus, cutting edge and to detect defects in surfaces of nickeltitanium (NiTi) instruments for endodontic retreatment.METHODS: The selected endodontic instruments (D-RaCe, ProTaper retreatment and Mtwo retreatment) were evaluated prior to their use in 30- and 50-fold magnification in scanning electron microscopy (SEM), for linear measurements of lateral cut edge areas and of the nucleus and the ratio between these measures. After use in simulated canals, faults in the active surface were analyzed by SEM with 30 and 50 times magnification, and 200 times magnification when faults were found. The images were examined by three evaluators, whose measurements were previously calibrated. The defects analyzed were crack, blunt and barb, and data were tabulated for analysis.RESULTS: The instruments studied differed in results. The D-RaCe system instruments had the highest nucleus:edge ratio, while ProTaper retreatment instruments yielded the lowest ratio. All instruments presented some defect, with the instruments Mtwo retreatment presenting two instruments with defects.CONCLUSION: All analyzed instruments presented some type of failure after using them for removal of the filling material of simulated root canals. The D-RaCe system presented the highest edge measurements and the smallest nucleus measurements, contrary to the ProTaper retreatment system, which presented the smallest edge measurements and the largest core measurements.
期刊介绍:
Cessation. The Revista Odonto Ciência is a peer-reviewed journal published online (ISSN 1980-6523), four times per year, supported by the Pontifical Catholic University of Rio Grande do Sul – Dental School since 1986. Its abbreviation is Rev Odonto Cienc, which should be used in references, bibliographic legends, and footnotes. The Revista Odonto Ciência is an international scientific journal dedicated to provide a forum for academics, researchers, and practitioners to communicate relevant basic, clinical, education, and epidemiological studies in Dentistry and related fields. The Journal seeks to publish articles on new conceptual models, innovative technology, alternative procedures or treatment to reduce disease burden in the general population or specific groups, thus contributing to translating science into practice and social development. Contributions falling into the following categories will be considered for publication: 1) original research reports of basic and applied oral sciences, epidemiological, and education studies; 2) review article; 3) case report. The Revista Odonto Ciência only accepts manuscripts written in English. Manuscripts submitted to this journal should not have been published before nor have publication pending elsewhere.