{"title":"An investigation of the effects of aspect ratio and opening on CSPSW and TSCSW","authors":"M. Labibzadeh, M. Bagheri, A. Khademalrasoul, K. Hossain","doi":"10.1108/ijsi-01-2022-0004","DOIUrl":null,"url":null,"abstract":"PurposeThis paper aims to study, the effects of opening shape, size and position as well as the aspect (height-to-length) ratio on the shear capacity, stiffness, ductility and energy dissipation capacity of triple-skin profiled steel-concrete composite shear wall (TSCSW) and investigate and compare them to those of concrete-stiffened steel plate shear walls (CSPSW). Two kinds of opening, circular and square, with different sizes and positions and two aspect ratios of 1:1 and 3:1 are considered in the simulations.Design/methodology/approachThis study presents a novel TSCSW and compares its behavior with the existing CSPSW under the effect of monotonic and cyclic loadings. TSCSW is composed of three corrugated steel plates filled with concrete. The two external side plates are connected to the concrete core by means of several intermediate fasteners and the third one is an inner steel plate embedded within the concrete panel. The internal plate is a buckling restrained plate surrounded by concrete. This is the main superiority of TSCSW over other kinds of existing composite shear walls.FindingsThe results show that the shear capacity and the energy dissipation capacity of the proposed composite wall, TSCSW, are respectively about 16 and 12% higher than those of CSPSW when there is no opening. If an opening is considered in the wall, as the size of the opening is increased, the shear capacity, stiffness, ductility and absorbed energy of the two walls are decreased similarly. The destructive effect of square openings on the performance of the walls is more than that of circular openings.Originality/valueThis is an original work.","PeriodicalId":45359,"journal":{"name":"International Journal of Structural Integrity","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2022-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Structural Integrity","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/ijsi-01-2022-0004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 2

Abstract

PurposeThis paper aims to study, the effects of opening shape, size and position as well as the aspect (height-to-length) ratio on the shear capacity, stiffness, ductility and energy dissipation capacity of triple-skin profiled steel-concrete composite shear wall (TSCSW) and investigate and compare them to those of concrete-stiffened steel plate shear walls (CSPSW). Two kinds of opening, circular and square, with different sizes and positions and two aspect ratios of 1:1 and 3:1 are considered in the simulations.Design/methodology/approachThis study presents a novel TSCSW and compares its behavior with the existing CSPSW under the effect of monotonic and cyclic loadings. TSCSW is composed of three corrugated steel plates filled with concrete. The two external side plates are connected to the concrete core by means of several intermediate fasteners and the third one is an inner steel plate embedded within the concrete panel. The internal plate is a buckling restrained plate surrounded by concrete. This is the main superiority of TSCSW over other kinds of existing composite shear walls.FindingsThe results show that the shear capacity and the energy dissipation capacity of the proposed composite wall, TSCSW, are respectively about 16 and 12% higher than those of CSPSW when there is no opening. If an opening is considered in the wall, as the size of the opening is increased, the shear capacity, stiffness, ductility and absorbed energy of the two walls are decreased similarly. The destructive effect of square openings on the performance of the walls is more than that of circular openings.Originality/valueThis is an original work.
纵横比和开口对CSPSW和TSSSW影响的研究
目的研究开孔形状、开孔尺寸、开孔位置以及开孔长高比对三层型钢-混凝土组合剪力墙(TSCSW)抗剪能力、刚度、延性和耗能能力的影响,并与混凝土加筋钢板剪力墙(CSPSW)进行对比研究。仿真中考虑了圆孔和方孔两种不同尺寸和位置的开口,宽高比分别为1:1和3:1。设计/方法/方法本研究提出了一种新型的TSCSW,并将其与现有的CSPSW在单调和循环荷载作用下的性能进行了比较。TSCSW由三个填充混凝土的波纹钢板组成。两个外部侧板通过若干中间紧固件连接到混凝土芯上,第三个侧板是嵌入在混凝土板内的内钢板。内板为混凝土包围的抗屈曲板。这是TSCSW相对于现有其他组合剪力墙的主要优势。结果表明:在不开孔情况下,TSCSW复合墙体的抗剪能力和消能能力分别比CSPSW高16%和12%左右;在考虑开孔的情况下,随着开孔尺寸的增大,两墙的抗剪能力、刚度、延性和吸收能均有相似的下降。方形开口对墙体性能的破坏作用大于圆形开口。这是一部原创作品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Structural Integrity
International Journal of Structural Integrity ENGINEERING, MULTIDISCIPLINARY-
CiteScore
5.40
自引率
14.80%
发文量
42
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信