A novel intraoperative continuous monitoring method combining dorsal cochlear nucleus action potentials monitoring with auditory nerve test system.

IF 2.6 3区 医学 Q1 OTORHINOLARYNGOLOGY
Makoto Hosoya, Yuriko Nagaoka, Takeshi Wakabayashi, Marie N Shimanuki, Takanori Nishiyama, Masafumi Ueno, Hiroyuki Ozawa, Naoki Oishi
{"title":"A novel intraoperative continuous monitoring method combining dorsal cochlear nucleus action potentials monitoring with auditory nerve test system.","authors":"Makoto Hosoya, Yuriko Nagaoka, Takeshi Wakabayashi, Marie N Shimanuki, Takanori Nishiyama, Masafumi Ueno, Hiroyuki Ozawa, Naoki Oishi","doi":"10.1186/s40463-023-00671-4","DOIUrl":null,"url":null,"abstract":"<p><p>Highly accurate real-time cochlear nerve monitoring to preserve cochlear nerve function is essential for simultaneous cochlear implantation and ipsilateral vestibular schwannoma resection. In the present study, we developed a novel real-time monitoring system that combines dorsal cochlear nucleus action potential monitoring with intracochlear stimulating electrodes (Auditory Nerve Test System, ANTS). We used this system for a case with vestibular schwannoma resection via the translabyrinthine approach. The monitoring system developed in this study detected highly reliable evoked potentials from the cochlear nerve every two seconds continuously during tumor resection. Near-total tumor resection was achieved, and cochlear implantation was performed successfully after confirming the preservation of cochlear nerve function in a case. The patient's hearing was well compensated by cochlear implantation after surgery. Our novel method continuously achieved real-time monitoring of the cochlear nerve every two seconds during vestibular schwannoma resection. The usefulness of this monitoring system for simultaneous tumor resection and cochlear implantation was demonstrated in the present case. The system developed in this study is compatible with continuous facial nerve monitoring. This highly accurate and novel monitoring method will broaden the number of candidates for this type of surgery in the future.</p>","PeriodicalId":16615,"journal":{"name":"Journal of Otolaryngology - Head & Neck Surgery","volume":"52 1","pages":"67"},"PeriodicalIF":2.6000,"publicationDate":"2023-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10557301/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Otolaryngology - Head & Neck Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40463-023-00671-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Highly accurate real-time cochlear nerve monitoring to preserve cochlear nerve function is essential for simultaneous cochlear implantation and ipsilateral vestibular schwannoma resection. In the present study, we developed a novel real-time monitoring system that combines dorsal cochlear nucleus action potential monitoring with intracochlear stimulating electrodes (Auditory Nerve Test System, ANTS). We used this system for a case with vestibular schwannoma resection via the translabyrinthine approach. The monitoring system developed in this study detected highly reliable evoked potentials from the cochlear nerve every two seconds continuously during tumor resection. Near-total tumor resection was achieved, and cochlear implantation was performed successfully after confirming the preservation of cochlear nerve function in a case. The patient's hearing was well compensated by cochlear implantation after surgery. Our novel method continuously achieved real-time monitoring of the cochlear nerve every two seconds during vestibular schwannoma resection. The usefulness of this monitoring system for simultaneous tumor resection and cochlear implantation was demonstrated in the present case. The system developed in this study is compatible with continuous facial nerve monitoring. This highly accurate and novel monitoring method will broaden the number of candidates for this type of surgery in the future.

一种将耳蜗背核动作电位监测与听神经测试系统相结合的术中连续监测新方法。
高度准确的实时耳蜗神经监测以保持耳蜗神经功能对于同时进行耳蜗植入和同侧前庭神经鞘瘤切除至关重要。在本研究中,我们开发了一种新的实时监测系统,该系统将耳蜗背核动作电位监测与耳蜗内刺激电极相结合(听觉神经测试系统,ANTS)。我们将该系统用于一例经迷路入路前庭神经鞘瘤切除术。本研究中开发的监测系统在肿瘤切除过程中连续每两秒检测一次来自耳蜗神经的高度可靠的诱发电位。在确认一例患者的耳蜗神经功能得到保留后,实现了近全肿瘤切除,并成功进行了人工耳蜗植入。手术后植入人工耳蜗,病人的听力得到了很好的补偿。我们的新方法在前庭神经鞘瘤切除过程中连续实现了每两秒对耳蜗神经的实时监测。该监测系统在同时进行肿瘤切除和耳蜗植入方面的实用性在本例中得到了证明。本研究开发的系统与面部神经连续监测兼容。这种高度准确和新颖的监测方法将在未来扩大这类手术的候选人数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.50
自引率
2.90%
发文量
0
审稿时长
6 weeks
期刊介绍: Journal of Otolaryngology-Head & Neck Surgery is an open access, peer-reviewed journal publishing on all aspects and sub-specialties of otolaryngology-head & neck surgery, including pediatric and geriatric otolaryngology, rhinology & anterior skull base surgery, otology/neurotology, facial plastic & reconstructive surgery, head & neck oncology, and maxillofacial rehabilitation, as well as a broad range of related topics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信