The influence of contrast enhancement and experience of observers on the assessment of mediastinal lymph nodes in sarcoidosis patients.

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Polish Journal of Radiology Pub Date : 2022-07-15 eCollection Date: 2022-01-01 DOI:10.5114/pjr.2022.118303
Magdalena Sobocinska, Marcin Białecki, Bartosz Sobocinski, Ida Martynowska, Jakub Ciescinski
{"title":"The influence of contrast enhancement and experience of observers on the assessment of mediastinal lymph nodes in sarcoidosis patients.","authors":"Magdalena Sobocinska,&nbsp;Marcin Białecki,&nbsp;Bartosz Sobocinski,&nbsp;Ida Martynowska,&nbsp;Jakub Ciescinski","doi":"10.5114/pjr.2022.118303","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to assess the influence of contrast enhancement (CE) and experience of observers on the assessment of chest lymph nodes in patients with sarcoidosis.</p><p><strong>Material and methods: </strong>A retrospective analysis of chest lymph nodes on computed tomography (CT) examinations, including CE and non-contrast-enhanced (non-CE) phase, was performed on 40 patients with proven diagnosis of sarcoidosis. Phases were separated, anonymized, and randomized. The assessment was performed by 5 observers: 2 general radiologists, 2 residents, and a senior chest CT expert.</p><p><strong>Results: </strong>There were no significant differences between radiologists and residents, apart from the determination of the 4R node short diameter on CE images. Agreement between the reference observer and both residents and specialists was equally high, without any significant difference in the assessment all chest nodes and hilar nodes, and between non-CE and CE images. There was a significant difference between all observers in the determination of the largest 4R node short diameter on non-CE images, but not on CE images. The number of affected node levels was found to be significantly higher when evaluated on CE images than on non-CE images. Compared to CE images, non-CE computed tomography has sensitivity of 0.94-1.00 and specificity of 0.98-1.00, depending on the observer.</p><p><strong>Conclusions: </strong>The application of contrast medium has a limited impact on the quality of assessment of the chest lymph nodes in patients with sarcoidosis, regardless of the experience of the observer.</p>","PeriodicalId":47128,"journal":{"name":"Polish Journal of Radiology","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2022-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d8/e7/PJR-87-47544.PMC9373862.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/pjr.2022.118303","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study was to assess the influence of contrast enhancement (CE) and experience of observers on the assessment of chest lymph nodes in patients with sarcoidosis.

Material and methods: A retrospective analysis of chest lymph nodes on computed tomography (CT) examinations, including CE and non-contrast-enhanced (non-CE) phase, was performed on 40 patients with proven diagnosis of sarcoidosis. Phases were separated, anonymized, and randomized. The assessment was performed by 5 observers: 2 general radiologists, 2 residents, and a senior chest CT expert.

Results: There were no significant differences between radiologists and residents, apart from the determination of the 4R node short diameter on CE images. Agreement between the reference observer and both residents and specialists was equally high, without any significant difference in the assessment all chest nodes and hilar nodes, and between non-CE and CE images. There was a significant difference between all observers in the determination of the largest 4R node short diameter on non-CE images, but not on CE images. The number of affected node levels was found to be significantly higher when evaluated on CE images than on non-CE images. Compared to CE images, non-CE computed tomography has sensitivity of 0.94-1.00 and specificity of 0.98-1.00, depending on the observer.

Conclusions: The application of contrast medium has a limited impact on the quality of assessment of the chest lymph nodes in patients with sarcoidosis, regardless of the experience of the observer.

增强造影剂对结节病患者纵隔淋巴结检查的影响及观察经验。
目的:本研究的目的是评估对比增强(CE)和观察者的经验对结节病患者胸部淋巴结评估的影响。材料和方法:回顾性分析40例结节病确诊患者的胸部淋巴结CT检查,包括CE和非造影增强(non-CE)期。阶段是分开的,匿名的,随机的。评估由5名观察员进行:2名普通放射科医生,2名住院医师和1名高级胸部CT专家。结果:除了CE图像上4R淋巴结短径的确定外,放射科医师与住院医师之间无显著差异。参考观察者与住院医师和专家之间的一致性同样高,在评估所有胸部淋巴结和肺门淋巴结以及非CE和CE图像之间没有任何显着差异。所有观察者在非CE图像上确定最大4R节点短直径有显著差异,但在CE图像上无显著差异。当在CE图像上评估时,发现受影响的节点水平的数量明显高于非CE图像。与CE图像相比,非CE计算机断层扫描的灵敏度为0.94-1.00,特异性为0.98-1.00,具体取决于观察者。结论:造影剂的应用对结节病患者胸部淋巴结评估质量的影响有限,与观察者的经验无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Polish Journal of Radiology
Polish Journal of Radiology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信