Percutaneous patent ductus arteriosus closure: Twelve years of experience

João Antunes Sarmento , Ana Correia-Costa , Edite Gonçalves , Maria João Baptista , João Carlos Silva , Jorge Moreira
{"title":"Percutaneous patent ductus arteriosus closure: Twelve years of experience","authors":"João Antunes Sarmento ,&nbsp;Ana Correia-Costa ,&nbsp;Edite Gonçalves ,&nbsp;Maria João Baptista ,&nbsp;João Carlos Silva ,&nbsp;Jorge Moreira","doi":"10.1016/j.repce.2020.09.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Patent ductus arteriosus, a persistent communication between the descending thoracic aorta and the pulmonary artery, is one of the most common congenital heart defects. Transcatheter occlusion is an effective alternative to surgery and is currently standard of care for most patients. The authors present the results from a single center after twelve years of experience using this technique.</p></div><div><h3>Methods</h3><p>Retrospective analysis of medical records from all patients referred to a tertiary center for percutaneous ductus closure between January 2006 and September 2018.</p></div><div><h3>Results</h3><p>A total of 221 patients were referred, with a mean age of 5.5 years-old (16 patients were infants, with the youngest aged four months). A Nit-Occlud® coil was used 139 times (62.9%), an Amplatzer™ duct occluder 79 times (35.7%), and vascular plugs were used three times. Percutaneous closure was achieved in every treated patient, with 1.4% maintaining residual shunting. Although higher overall coil device implantation was noted, duct occluder usage has been greater since 2011. Of all the coils, 55% were either 4x4 or 5x4 mm, and 73% of all Amplatzer duct occluders were either 6x4 or 8x6 mm, which correlates to the majority of patients having a small to moderately sized ductus. No complications were noted during the procedure, with a 1.8% post-procedure complication rate (one device embolization after 48 hours and three cases of loss of arterial pulse).</p></div><div><h3>Conclusions</h3><p>Percutaneous patent ductus arteriosus closure was safe and effective in this setting, with a low global complication rate and similar outcomes to most equivalent centers.</p></div>","PeriodicalId":101121,"journal":{"name":"Revista Portuguesa de Cardiologia (English Edition)","volume":"40 8","pages":"Pages 561-568"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.repce.2020.09.009","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Portuguesa de Cardiologia (English Edition)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2174204921002142","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Patent ductus arteriosus, a persistent communication between the descending thoracic aorta and the pulmonary artery, is one of the most common congenital heart defects. Transcatheter occlusion is an effective alternative to surgery and is currently standard of care for most patients. The authors present the results from a single center after twelve years of experience using this technique.

Methods

Retrospective analysis of medical records from all patients referred to a tertiary center for percutaneous ductus closure between January 2006 and September 2018.

Results

A total of 221 patients were referred, with a mean age of 5.5 years-old (16 patients were infants, with the youngest aged four months). A Nit-Occlud® coil was used 139 times (62.9%), an Amplatzer™ duct occluder 79 times (35.7%), and vascular plugs were used three times. Percutaneous closure was achieved in every treated patient, with 1.4% maintaining residual shunting. Although higher overall coil device implantation was noted, duct occluder usage has been greater since 2011. Of all the coils, 55% were either 4x4 or 5x4 mm, and 73% of all Amplatzer duct occluders were either 6x4 or 8x6 mm, which correlates to the majority of patients having a small to moderately sized ductus. No complications were noted during the procedure, with a 1.8% post-procedure complication rate (one device embolization after 48 hours and three cases of loss of arterial pulse).

Conclusions

Percutaneous patent ductus arteriosus closure was safe and effective in this setting, with a low global complication rate and similar outcomes to most equivalent centers.

经皮动脉导管未闭闭合:12年经验
动脉导管未闭是胸降主动脉和肺动脉之间的一种持续的交通,是最常见的先天性心脏缺陷之一。经导管闭塞是一种有效的替代手术,目前是大多数患者的标准护理。作者介绍了使用该技术12年后单个中心的结果。方法回顾性分析2006年1月至2018年9月在三级中心进行经皮导管闭合的所有患者的病历。结果共纳入221例患者,平均年龄5.5岁(16例为婴儿,最小4个月)。niti - occlud®线圈使用139次(62.9%),Amplatzer™导管闭塞器使用79次(35.7%),血管塞使用3次。所有接受治疗的患者均实现了经皮闭合,1.4%的患者维持了残留的分流。虽然注意到线圈装置植入的总体增加,但自2011年以来,导管闭塞器的使用有所增加。在所有线圈中,55%为4x4或5x4毫米,73%的Amplatzer导管闭塞器为6x4或8x6毫米,这与大多数患者的小到中等大小的导管有关。术中无并发症,术后并发症发生率为1.8%(1例48小时后器械栓塞,3例动脉脉搏消失)。结论经皮动脉导管未闭闭合术安全有效,整体并发症发生率低,结果与大多数同等中心相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信