{"title":"Evaluation of Legiolert for Quantification of Legionella pneumophila from Bath Water Samples.","authors":"Hiroaki Inoue, Masumi Baba, Seina Tayama","doi":"10.4265/bio.25.179","DOIUrl":null,"url":null,"abstract":"<p><p>Testing for Legionella spp. in public bath water samples is regulated in Japan. In this study, we used a total of 132 public bath water samples to compare the performance of Legiolert® and the conventional plate culture method for the enumeration of Legionella pneumophila. When Legiolert and plate culturing were performed at the same detection limit, L. pneumophila was detected in 26.5% of 132 samples by Legiolert, while 12.9% contained Legionella spp. (11.4% contained L. pneumophila) based on the plate culture method. Moreover, results of 83.3% of the total samples were consistent between the two methods, meaning that they were both positive or both negative. In this study, we demonstrated that Legiolert is a simpler and more effective method of monitoring for L. pneumophila in bath water samples.</p>","PeriodicalId":8777,"journal":{"name":"Biocontrol science","volume":"25 3","pages":"179-182"},"PeriodicalIF":0.9000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biocontrol science","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.4265/bio.25.179","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 8
Abstract
Testing for Legionella spp. in public bath water samples is regulated in Japan. In this study, we used a total of 132 public bath water samples to compare the performance of Legiolert® and the conventional plate culture method for the enumeration of Legionella pneumophila. When Legiolert and plate culturing were performed at the same detection limit, L. pneumophila was detected in 26.5% of 132 samples by Legiolert, while 12.9% contained Legionella spp. (11.4% contained L. pneumophila) based on the plate culture method. Moreover, results of 83.3% of the total samples were consistent between the two methods, meaning that they were both positive or both negative. In this study, we demonstrated that Legiolert is a simpler and more effective method of monitoring for L. pneumophila in bath water samples.
期刊介绍:
The Biocontrol Science provides a medium for the publication of original articles, concise notes, and review articles on all aspects of science and technology of biocontrol.